Nano X-ray Tomography at the CARNAÚBA Beamline (SIRIUS-LNLS) in diamond mineral inclusions

Abstract The CARNAÚBA beamline is an X-ray nanoprobe that enables nanoscale tomography by scanning a beam smaller than 500 nm. It features a high flux (10 9 to 10 10 ph/s/100 mA at 12 keV) and simultaneous acquisition of transmission and fluorescence data, through a photodiode and two fluorescence detectors, respectively, allowing the mapping of various elements and facilitating 3D images with multiple contrasts. This technique was applied to analyze two distinct minerals trapped in a diamond. Tomography measurements required precise alignment of the inclusions at different rotation angles, conducted at 12 keV over a scanned area of 100x100 µm 2 . The experiment itself involved 7 hours of data acquisition over a scanned area of 80x80 µm 2 , resulting in voxel sizes of 0.8x0.8x0.8 µm 3 . Data reconstruction was performed using a modified version of Chang’s method for fluorescence data, incorporating µ-Tomography reconstruction to address diamond-related self-absorption effects. This technique allowed us to identify different types of geological features. We present here the case of two mineral inclusions in the same diamond.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012178
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nano X-ray Tomography at the CARNAÚBA Beamline (SIRIUS-LNLS) in diamond mineral inclusions

Francisco M. C. da Silva, Paola Ferraz, Tiago Jalowitzki, Fernanda Gervasoni et al.
Journal of Physics Conference Series
Advanced X-ray Imaging Techniques
article

Nano X-ray Tomography at the CARNAÚBA Beamline (SIRIUS-LNLS) in diamond mineral inclusions

Francisco M. C. da Silva, Paola Ferraz, Tiago Jalowitzki, Fernanda Gervasoni, Antônio Pinto do Nascimento Neto, H. Tolentino, Eduardo X. Miqueles, Carolina Camarda, João Oliveira
article en

Abstract

Abstract The CARNAÚBA beamline is an X-ray nanoprobe that enables nanoscale tomography by scanning a beam smaller than 500 nm. It features a high flux (10 9 to 10 10 ph/s/100 mA at 12 keV) and simultaneous acquisition of transmission and fluorescence data, through a photodiode and two fluorescence detectors, respectively, allowing the mapping of various elements and facilitating 3D images with multiple contrasts. This technique was applied to analyze two distinct minerals trapped in a diamond. Tomography measurements required precise alignment of the inclusions at different rotation angles, conducted at 12 keV over a scanned area of 100x100 µm 2 . The experiment itself involved 7 hours of data acquisition over a scanned area of 80x80 µm 2 , resulting in voxel sizes of 0.8x0.8x0.8 µm 3 . Data reconstruction was performed using a modified version of Chang’s method for fluorescence data, incorporating µ-Tomography reconstruction to address diamond-related self-absorption effects. This technique allowed us to identify different types of geological features. We present here the case of two mineral inclusions in the same diamond.

Journal of Physics Conference SeriesVol. 3010(1)
Universidade de Brasília (BR), Universidade Federal de Pelotas (BR), Brazilian Synchrotron Light Laboratory (BR), Brazilian Center for Research in Energy and Materials (BR), European X-Ray Free-Electron Laser (DE)
Openalex Percentile: Top 81%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.