A 250 Hz fast shutter with flexible sampling schemes for low-dose XPCS experiments at beamline P10 at PETRA III

Abstract Low-dose X-ray photon correlation spectroscopy experiments on biological samples can be used to investigate the structure formation and underlying dynamics during phase separation, denaturation, and gelation. However, the use of intensive X-ray beams as an investigative tool is limited due to the susceptibility of biological samples to radiation-induced changes. XPCS in particular requires recording a series of high-frame-rate images to capture fast dynamics. In such cases, a fast X-ray shutter system is required to minimize beam damage to the samples by allowing a flexible delay between two images. Here we show how a fast (250 Hz) X-ray shutter system, built by the University of Siegen in close collaboration with DESY, improves low-dose XPCS capabilities at the P10 beamline at PETRA III. We found that by employing this shutter system in a logarithmic sampling scheme, the absorbed X-ray dose on the samples could be significantly decreased.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012095
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 250 Hz fast shutter with flexible sampling schemes for low-dose XPCS experiments at beamline P10 at PETRA III

Sonja Timmermann, Nimmi Das Anthuparambil, Michael Sprung, Marvin Kowalski et al.
Journal of Physics Conference Series
Nuclear Physics and Applications
article

A 250 Hz fast shutter with flexible sampling schemes for low-dose XPCS experiments at beamline P10 at PETRA III

Sonja Timmermann, Nimmi Das Anthuparambil, Michael Sprung, Marvin Kowalski, Michael Paulus, Fabian Westermeier, Christian Gutt, Michelle Dargasz, S. Heidbrink, M. Ziolkowski, Daniel Weschke
article en

Abstract

Abstract Low-dose X-ray photon correlation spectroscopy experiments on biological samples can be used to investigate the structure formation and underlying dynamics during phase separation, denaturation, and gelation. However, the use of intensive X-ray beams as an investigative tool is limited due to the susceptibility of biological samples to radiation-induced changes. XPCS in particular requires recording a series of high-frame-rate images to capture fast dynamics. In such cases, a fast X-ray shutter system is required to minimize beam damage to the samples by allowing a flexible delay between two images. Here we show how a fast (250 Hz) X-ray shutter system, built by the University of Siegen in close collaboration with DESY, improves low-dose XPCS capabilities at the P10 beamline at PETRA III. We found that by employing this shutter system in a logarithmic sampling scheme, the absorbed X-ray dose on the samples could be significantly decreased.

Journal of Physics Conference SeriesVol. 3010(1)
TU Dortmund University (DE), University of Siegen (DE), Folkwang University of the Arts (DE), Deutsches Elektronen-Synchrotron DESY (DE)
Openalex Percentile: Top 81%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A 250 Hz fast shutter with flexible sampling schemes for low-dose XPCS experiments at beamline P10 at PETRA III — Sonja Timmermann, Nimmi Das Anthuparambil, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS