Toward high-speed and high-accuracy single crystal X-ray diffraction measurements using the integration-type detector CITIUS

Abstract The integration-type two-dimensional detector CITIUS has a high saturation count rate, capable of measurements up to 600 Mcps/pixel (at 12.4 keV and a frame rate of 17.4 kHz). Aiming to integrate the CITIUS detector for X-ray diffraction measurements at undulator beamlines, we conducted proof-of-concept experiments at SPring-8 BL29XU using 30 keV X-rays and a ruby single-crystal standard sample. The goal of integrating CITIUS is to obtain data at high speed and accuracy, which is critical for precise single-crystal X-ray structural analyses. The experimental results confirmed that CITIUS is applicable to single-crystal diffraction experiments using 30 keV X-rays. We observed that peak intensities can be measured at least 0.9 Mcps/pixel (at a frame rate of 1 kHz), corresponding to 15.7 Mcps/pixel at a 17.4 kHz frame rate. Several challenges were also identified. Developments are ongoing to solve these issues.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012171
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Toward high-speed and high-accuracy single crystal X-ray diffraction measurements using the integration-type detector CITIUS

Yasuhiko Imai, Yasumasa Joti, Takaki Hatsui, T N Hiraki et al.
Journal of Physics Conference Series
Advanced X-ray Imaging Techniques
article

Toward high-speed and high-accuracy single crystal X-ray diffraction measurements using the integration-type detector CITIUS

Yasuhiko Imai, Yasumasa Joti, Takaki Hatsui, T N Hiraki, H. Nishino, Kazuo Ozaki, Y. Honjo
article en

Abstract

Abstract The integration-type two-dimensional detector CITIUS has a high saturation count rate, capable of measurements up to 600 Mcps/pixel (at 12.4 keV and a frame rate of 17.4 kHz). Aiming to integrate the CITIUS detector for X-ray diffraction measurements at undulator beamlines, we conducted proof-of-concept experiments at SPring-8 BL29XU using 30 keV X-rays and a ruby single-crystal standard sample. The goal of integrating CITIUS is to obtain data at high speed and accuracy, which is critical for precise single-crystal X-ray structural analyses. The experimental results confirmed that CITIUS is applicable to single-crystal diffraction experiments using 30 keV X-rays. We observed that peak intensities can be measured at least 0.9 Mcps/pixel (at a frame rate of 1 kHz), corresponding to 15.7 Mcps/pixel at a 17.4 kHz frame rate. Several challenges were also identified. Developments are ongoing to solve these issues.

Journal of Physics Conference SeriesVol. 3010(1)
SPring-8 (JP), Japan Synchrotron Radiation Research Institute (JP)
Openalex Percentile: Top 81%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Toward high-speed and high-accuracy single crystal X-ray diffraction measurements using the integration-type detector CITIUS — Yasuhiko Imai, Yasumasa Joti, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS