Efficient Carbon Cleaning of Soft X-ray Optical Elements at NSRRC

Abstract Carbon contamination on optics is observed at our soft X-ray beamlines. UV/ozone cleaning technique is used to eliminate the carbon contaminations at National Synchrotron Radiation Research Center (NSRRC). In the past, a mercury lamp was utilised as the light source of UV/ozone cleaning technique. Due to its larger divergence, the lamp must be placed close to the target optics. That is a time-consuming and high-risk task because of the tight space in the mirror chamber. Recently, two carbon cleaning systems were developed in NSRRC. The first one is to use an excimer laser as the light source and the second one is to use a deuterium lamp in conjunction with a collimator. The experimental results show that the former solution is more efficient than the latter. Besides, the process of carbon cleaning can be significantly simplified. The best cleaning rate of the excimer laser is 5.7 nm/hr at a distance of 1000 mm from the light source to the sample.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012080
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient Carbon Cleaning of Soft X-ray Optical Elements at NSRRC

Yin‐Yu Lee, Tzu-Ping Huang, Liang-Jen Huang, Chiun Hsu
4 links
Journal of Physics Conference Series
Advanced X-ray and CT Imaging
article

Efficient Carbon Cleaning of Soft X-ray Optical Elements at NSRRC

Yin‐Yu Lee, Tzu-Ping Huang, Liang-Jen Huang, Chiun Hsu
article en

Abstract

Abstract Carbon contamination on optics is observed at our soft X-ray beamlines. UV/ozone cleaning technique is used to eliminate the carbon contaminations at National Synchrotron Radiation Research Center (NSRRC). In the past, a mercury lamp was utilised as the light source of UV/ozone cleaning technique. Due to its larger divergence, the lamp must be placed close to the target optics. That is a time-consuming and high-risk task because of the tight space in the mirror chamber. Recently, two carbon cleaning systems were developed in NSRRC. The first one is to use an excimer laser as the light source and the second one is to use a deuterium lamp in conjunction with a collimator. The experimental results show that the former solution is more efficient than the latter. Besides, the process of carbon cleaning can be significantly simplified. The best cleaning rate of the excimer laser is 5.7 nm/hr at a distance of 1000 mm from the light source to the sample.

Journal of Physics Conference SeriesVol. 3010(1)
National Synchrotron Radiation Research Center (TW)
Openalex Percentile: Top 88%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Efficient Carbon Cleaning of Soft X-ray Optical Elements at NSRRC — Yin‐Yu Lee, Tzu-Ping Huang, et al. · Journal of Physics Conference Series (2025) | TGRS Research Map | TGRS