Simulation and Measurement of Horizontal Emittance via Undulator High Harmonics at the APS-U

Abstract The transition from 3rd to 4th generation synchrotron light sources via Diffraction Limited Storage Rings (DLSRs) is largely de=ined by the reduction of horizontal emittances and, in turn, achieving more uniform transverse X-ray beam pro=iles. Previously at Advanced Photon Source (APS), SPECTRA simulations were performed to compare to the vertical emittance measurements made at the IEX undulator and beamline. The alignment in measurement and simulation drove the desire to measure the horizontal emittance at the APS-Upgrade. Simulations in SPECTRA and ongoing work in Synchrotron Radiation Workshop (SRW) guide our experimental strategy. In the present work, results from SRW will be presented. We will then conclude with commissioning measurements of beam size and emittance in the APS-U as well as a discussion on the advantages to the undulator high harmonics method when compared to other methods at the APS-U.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012032
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation and Measurement of Horizontal Emittance via Undulator High Harmonics at the APS-U

Emmanuel Aneke, J. W. Freeland, Kent Wootton, J. L. McChesney et al.
Journal of Physics Conference Series
Particle Accelerators and Free-Electron Lasers
article

Simulation and Measurement of Horizontal Emittance via Undulator High Harmonics at the APS-U

Emmanuel Aneke, J. W. Freeland, Kent Wootton, J. L. McChesney, Fanny Rodolakis, Hao Zheng
article en

Abstract

Abstract The transition from 3rd to 4th generation synchrotron light sources via Diffraction Limited Storage Rings (DLSRs) is largely de=ined by the reduction of horizontal emittances and, in turn, achieving more uniform transverse X-ray beam pro=iles. Previously at Advanced Photon Source (APS), SPECTRA simulations were performed to compare to the vertical emittance measurements made at the IEX undulator and beamline. The alignment in measurement and simulation drove the desire to measure the horizontal emittance at the APS-Upgrade. Simulations in SPECTRA and ongoing work in Synchrotron Radiation Workshop (SRW) guide our experimental strategy. In the present work, results from SRW will be presented. We will then conclude with commissioning measurements of beam size and emittance in the APS-U as well as a discussion on the advantages to the undulator high harmonics method when compared to other methods at the APS-U.

Journal of Physics Conference SeriesVol. 3010(1)
Northwestern University (US), Argonne National Laboratory (US)
Openalex Percentile: Top 89%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.