On the Influence of Parallax Effects in Thick Silicon Sensors in Coherent Diffraction Imaging

Abstract Structure determination of, e.g., single molecules is a key application of X-ray free-electron lasers (XFELs) and 4 th generation synchrotron sources, particularly using the coherent and pulsed X-ray radiation from XFELs. Scientific interest focuses on understanding the physical, biological, and chemical properties of samples at the nanometer scale. The X-rays from XFELs enable Coherent X-ray Diffraction Imaging (CXDI), where coherent X-rays irradiate a sample, and a far-field diffraction pattern is captured by an imaging detector. By the nature of the underlying physics, the resolution, at which the molecular structure of a sample can be probed with the CXDI technique, is limited by the wavelength of the X-ray radiation and the exposure time if a detector can record the diffraction pattern up to very large scattering angles. The resolution that can be achieved under real experimental conditions, depends strongly on additional parameters. The Shannon pixel size, linked to the detector resolution, the coherent dose that can be deposited in the sample without changing its structure, the image contrast, and the signal-to-noise ratio of the detected scattered radiation at high q , i.e., at high scattering angles 2Θ, have a strong influence on the resolution. The signal-to-noise ratio at high q defines the “effective” maximum solid angle in a specific experiment setup at which a detector can efficiently detect a signal and in consequence determines the achievable resolution. The image contrast defines how well bright image features can be distinguished from dark ones. We present the preliminary results of our study on the influence of the point spread function on the signal-to-noise ratio, image contrast, position resolution, and achievable sample resolution for different pixel sizes.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012135
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On the Influence of Parallax Effects in Thick Silicon Sensors in Coherent Diffraction Imaging

M. Kuster, Tonn Rüter, Steffen Hauf, L. Strüder et al.
Journal of Physics Conference Series
Advanced X-ray Imaging Techniques
article

On the Influence of Parallax Effects in Thick Silicon Sensors in Coherent Diffraction Imaging

M. Kuster, Tonn Rüter, Steffen Hauf, L. Strüder, Robert Hartmann, P. Holl
article en

Abstract

Abstract Structure determination of, e.g., single molecules is a key application of X-ray free-electron lasers (XFELs) and 4 th generation synchrotron sources, particularly using the coherent and pulsed X-ray radiation from XFELs. Scientific interest focuses on understanding the physical, biological, and chemical properties of samples at the nanometer scale. The X-rays from XFELs enable Coherent X-ray Diffraction Imaging (CXDI), where coherent X-rays irradiate a sample, and a far-field diffraction pattern is captured by an imaging detector. By the nature of the underlying physics, the resolution, at which the molecular structure of a sample can be probed with the CXDI technique, is limited by the wavelength of the X-ray radiation and the exposure time if a detector can record the diffraction pattern up to very large scattering angles. The resolution that can be achieved under real experimental conditions, depends strongly on additional parameters. The Shannon pixel size, linked to the detector resolution, the coherent dose that can be deposited in the sample without changing its structure, the image contrast, and the signal-to-noise ratio of the detected scattered radiation at high q , i.e., at high scattering angles 2Θ, have a strong influence on the resolution. The signal-to-noise ratio at high q defines the “effective” maximum solid angle in a specific experiment setup at which a detector can efficiently detect a signal and in consequence determines the achievable resolution. The image contrast defines how well bright image features can be distinguished from dark ones. We present the preliminary results of our study on the influence of the point spread function on the signal-to-noise ratio, image contrast, position resolution, and achievable sample resolution for different pixel sizes.

Journal of Physics Conference SeriesVol. 3010(1)
PNSensor (Germany) (DE), European X-Ray Free-Electron Laser (DE)
Openalex Percentile: Top 82%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.