Characterization of the LCLS-II X-rays with Imagers, Power Meters and Fluorescence Intensity Monitors

Abstract The LCLS-II superconducting accelerator has begun operations and has been producing x-rays since August 2023. The current parameters are a photon energy range from 250 eV to 3.8 keV and a maximum repetition rate of 8.29 kHz. Imagers have determined the x-ray beam dimensions and the divergence. The absorption edges of solid filters were used to calibrate the photon energy and evaluate the FEL bandwidth from the hard x-ray undulator. A power meter measured the pulse energy at 2.5 keV. Power meters have ascertained the beamline transmission at the TMO and RIX instruments. The Fluorescence Intensity Monitor (FIM) provides a normalization of the x-ray intensity at the RIX endstations. The signal-to-noise ratio of the FIM has been improved by an analysis of the entire detector waveforms.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012100
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of the LCLS-II X-rays with Imagers, Power Meters and Fluorescence Intensity Monitors

Alberto Lutman, Douglas Garratt, Oliver Alexander, Philip Heimann et al.
Journal of Physics Conference Series
Medical Imaging Techniques and Applications
article

Characterization of the LCLS-II X-rays with Imagers, Power Meters and Fluorescence Intensity Monitors

Alberto Lutman, Douglas Garratt, Oliver Alexander, Philip Heimann, Ming‐Fu Lin, Georgi L. Dakovski, Stefan Moeller, Yuantao Ding, W. F. Schlotter, H.-D. Nuhn, James Cryan, Vincent Esposito, Razib Obaid, Kristjan Kunnus, K. Nakahara, Matt Seaberg
article en

Abstract

Abstract The LCLS-II superconducting accelerator has begun operations and has been producing x-rays since August 2023. The current parameters are a photon energy range from 250 eV to 3.8 keV and a maximum repetition rate of 8.29 kHz. Imagers have determined the x-ray beam dimensions and the divergence. The absorption edges of solid filters were used to calibrate the photon energy and evaluate the FEL bandwidth from the hard x-ray undulator. A power meter measured the pulse energy at 2.5 keV. Power meters have ascertained the beamline transmission at the TMO and RIX instruments. The Fluorescence Intensity Monitor (FIM) provides a normalization of the x-ray intensity at the RIX endstations. The signal-to-noise ratio of the FIM has been improved by an analysis of the entire detector waveforms.

Journal of Physics Conference SeriesVol. 3010(1)
SLAC National Accelerator Laboratory (US), Linac Coherent Light Source (US), Imperial College London (GB)
Openalex Percentile: Top 80%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.