Status of Pulsed Wire Magnet Field Measurement Set-up at HZB/BESSY

Abstract The IVU32 is the world’s first in-vacuum APPLE II undulator currently under development at HZB. Magnetic characterisation and tuning of this short-period small-gap device will be carried out using measurements with an in-vacuum Hall probe bench and moving wire system, as well as with a pulsed wire measurement (PWM) setup. The PWM technique is an especially useful solution for measuring the magnetic field in limited undulator gaps, such as those found in in-vacuum and cryogenic devices. The pulsed wire system at HZB enables a complete characterization of the undulator magnetic field and provides a cost-efficient technique for fast and easy measurements. We present the state of development of the pulsed wire system at HZB and discuss the limitations of the method, for example, due to the specific wire properties that influence the error increase and thus measurement accuracy.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012017
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Status of Pulsed Wire Magnet Field Measurement Set-up at HZB/BESSY

J. Bahrdt, Edward Rial, Carsten Kuhn, W. Frentrup et al.
Journal of Physics Conference Series
Superconducting Materials and Applications
article

Status of Pulsed Wire Magnet Field Measurement Set-up at HZB/BESSY

J. Bahrdt, Edward Rial, Carsten Kuhn, W. Frentrup, Christoph Rethfeldt, Stefan Grimmer, Kurosh Karimi, Sebastian Knaack, Atoosa Meseck, Nasim Fallahi
article en

Abstract

Abstract The IVU32 is the world’s first in-vacuum APPLE II undulator currently under development at HZB. Magnetic characterisation and tuning of this short-period small-gap device will be carried out using measurements with an in-vacuum Hall probe bench and moving wire system, as well as with a pulsed wire measurement (PWM) setup. The PWM technique is an especially useful solution for measuring the magnetic field in limited undulator gaps, such as those found in in-vacuum and cryogenic devices. The pulsed wire system at HZB enables a complete characterization of the undulator magnetic field and provides a cost-efficient technique for fast and easy measurements. We present the state of development of the pulsed wire system at HZB and discuss the limitations of the method, for example, due to the specific wire properties that influence the error increase and thus measurement accuracy.

Journal of Physics Conference SeriesVol. 3010(1)
Johannes Gutenberg University Mainz (DE), Helmholtz-Zentrum Berlin für Materialien und Energie (DE), University Medical Center of the Johannes Gutenberg University Mainz (DE)
Openalex Percentile: Top 88%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.