The Mechanical Design and Construction of Transmission X-ray Microscopy (TXM) Endstation at TPS 31A2

Abstract In this article, we discuss the key issues related to the design and construction of the Transmission X-ray Microscopy (TXM) endstation. We address the major challenges encountered, particularly those related to vibration during the assembly and alignment of optical components. Another significant focus is the wobble observed in the rotary stage and the misalignment between various stages of the TXM endstation. We evaluate the impact of these issues on overall performance and describe the measures implemented to mitigate them, ensuring precision and stability during experiments.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2025-05-01
DOI
https://doi.org/10.1088/1742-6596/3010/1/012092
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Mechanical Design and Construction of Transmission X-ray Microscopy (TXM) Endstation at TPS 31A2

Gung-Chian Yin, Ming-Ying Hsu, Yu-Shan Huang, Changbo Fu et al.
Journal of Physics Conference Series
Advanced X-ray Imaging Techniques
article

The Mechanical Design and Construction of Transmission X-ray Microscopy (TXM) Endstation at TPS 31A2

Gung-Chian Yin, Ming-Ying Hsu, Yu-Shan Huang, Changbo Fu, Chien-Yu Lee, Yung-Chien Chou, Bo-Yi Chen, Shih-Ting Lo, Yen‐Fang Song, Ying-Shuo Tseng, Chao-Chih Chiu, Hsiu‐Chien Chan
article en

Abstract

Abstract In this article, we discuss the key issues related to the design and construction of the Transmission X-ray Microscopy (TXM) endstation. We address the major challenges encountered, particularly those related to vibration during the assembly and alignment of optical components. Another significant focus is the wobble observed in the rotary stage and the misalignment between various stages of the TXM endstation. We evaluate the impact of these issues on overall performance and describe the measures implemented to mitigate them, ensuring precision and stability during experiments.

Journal of Physics Conference SeriesVol. 3010(1)
National Synchrotron Radiation Research Center (TW)
Openalex Percentile: Top 82%
Advanced X-ray Imaging Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.