Measurement of Hourly Tear Volume Variation using Smartphone Meniscometer: A 24-Hour Pilot Study

This pilot study examines the tear volume dynamics in human subjects using a smartphone-based meniscometer (SPM) being developed, which enables non-invasive measurements in non-clinical settings. The diurnal tear volume variation for five healthy male volunteers was obtained by measuring tear meniscus radius (TMR) every one hour for a period of 24 hours. The results were found to be consistent with the reported data in the literature showing highest TMR in the early morning (8:00-10:00 AM) which gradually decreased till noon and remained stable. In contrast to previous studies that typically collected data every 3-4 hours during the day with limited data points, the current study, which examined TMR variations every hour, captured subtle periodic fluctuations in TMR throughout both day and night, highlighting individual variability. Each participant displayed unique TMR peaks and oscillations that may reflect their individual body constitution, hormonal rhythms, and homeostatic responses to environmental changes. These findings demonstrate the feasibility of SPM for continuous tear volume monitoring outside of clinical settings and provide new insights into the natural circadian variation of tear volume. Further studies with larger and more diverse samples are needed to validate these TMR patterns and their association with ocular symptoms and tear-related disorders, including dry eye disease.

Authors

Institutions

Publication Details

Published
2024-11-28
DOI
https://doi.org/10.1145/3715020.3715065
Primary Topic
Ocular Surface and Contact Lens
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Hourly Tear Volume Variation using Smartphone Meniscometer: A 24-Hour Pilot Study

Chanda Rajurkar, Yoshiro Okazaki, B. Murugan, Gopinath Mudhana
Ocular Surface and Contact Lens
article

Measurement of Hourly Tear Volume Variation using Smartphone Meniscometer: A 24-Hour Pilot Study

Chanda Rajurkar, Yoshiro Okazaki, B. Murugan, Gopinath Mudhana
article en

Abstract

This pilot study examines the tear volume dynamics in human subjects using a smartphone-based meniscometer (SPM) being developed, which enables non-invasive measurements in non-clinical settings. The diurnal tear volume variation for five healthy male volunteers was obtained by measuring tear meniscus radius (TMR) every one hour for a period of 24 hours. The results were found to be consistent with the reported data in the literature showing highest TMR in the early morning (8:00-10:00 AM) which gradually decreased till noon and remained stable. In contrast to previous studies that typically collected data every 3-4 hours during the day with limited data points, the current study, which examined TMR variations every hour, captured subtle periodic fluctuations in TMR throughout both day and night, highlighting individual variability. Each participant displayed unique TMR peaks and oscillations that may reflect their individual body constitution, hormonal rhythms, and homeostatic responses to environmental changes. These findings demonstrate the feasibility of SPM for continuous tear volume monitoring outside of clinical settings and provide new insights into the natural circadian variation of tear volume. Further studies with larger and more diverse samples are needed to validate these TMR patterns and their association with ocular symptoms and tear-related disorders, including dry eye disease.

Waseda University (JP), Vellore Institute of Technology University (IN)
Affordable and clean energy
Openalex Percentile: Top 59%
Ocular Surface and Contact Lens
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.