3D-Printed Variable-Length Magnetically Steered Catheter Tip for Enhanced Access in Aneurysm Interventions

Recent catheter designs have considered the use of magnetically active soft continuum robots controlled via external magnetic actuation systems. These have proven effective for minimally invasive applications due to their soft structure, high dexterity, and wireless actuation, all at small scales. Single and multiple magnetic segment configurations have been proposed to allow tip-only control or full shape-forming, respectively. However, these approaches utilize fixed-length magnetic segments, which require advancement from the proximal end to enhance the reachability and workspace coverage of the steerable tip. To address this limitation, we propose a dual-actuated catheter tip design comprising a 3D-printed soft tendon-driven helical body for length adaptability coupled with a tip-mounted permanent magnet for steering. We achieve a compact design of 2.4 mm outer diameter and 18 mm nominal length, suitable for carotid artery aneurysm intervention. An existing analytical model based on the Euler-Bernoulli beam theory is adapted to predict tip deflection and tip angle under magnetic actuation at three different actuation lengths: contracted, normal, and extended. We demonstrate tip length actuation spanning from a 37.2% reduction to a 35.6% extension, corresponding to 11.3 mm and 24.4 mm when fully contracted and extended, respectively. The experimental magnetic actuation shows a maximum deflection angle of 89.5° with >68° achievable across all length configurations. We subsequently demonstrate how the proposed hybrid tendon and magnetic actuation approach enables enhanced workspace access when compared to a fixed-length design, improving access within simple and more complex aneurysm phantoms.

Authors

Institutions

Publication Details

Published
2025-04-22
DOI
https://doi.org/10.1109/robosoft63089.2025.11020882
Citations
3
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
4.17

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D-Printed Variable-Length Magnetically Steered Catheter Tip for Enhanced Access in Aneurysm Interventions

James H. Chandler, Pietro Valdastri, Muhammad Naveed Khalid
3 citations
Intracranial Aneurysms: Treatment and Complications
4.17
article

3D-Printed Variable-Length Magnetically Steered Catheter Tip for Enhanced Access in Aneurysm Interventions

James H. Chandler, Pietro Valdastri, Muhammad Naveed Khalid
article en
3 citations

Abstract

Recent catheter designs have considered the use of magnetically active soft continuum robots controlled via external magnetic actuation systems. These have proven effective for minimally invasive applications due to their soft structure, high dexterity, and wireless actuation, all at small scales. Single and multiple magnetic segment configurations have been proposed to allow tip-only control or full shape-forming, respectively. However, these approaches utilize fixed-length magnetic segments, which require advancement from the proximal end to enhance the reachability and workspace coverage of the steerable tip. To address this limitation, we propose a dual-actuated catheter tip design comprising a 3D-printed soft tendon-driven helical body for length adaptability coupled with a tip-mounted permanent magnet for steering. We achieve a compact design of 2.4 mm outer diameter and 18 mm nominal length, suitable for carotid artery aneurysm intervention. An existing analytical model based on the Euler-Bernoulli beam theory is adapted to predict tip deflection and tip angle under magnetic actuation at three different actuation lengths: contracted, normal, and extended. We demonstrate tip length actuation spanning from a 37.2% reduction to a 35.6% extension, corresponding to 11.3 mm and 24.4 mm when fully contracted and extended, respectively. The experimental magnetic actuation shows a maximum deflection angle of 89.5° with >68° achievable across all length configurations. We subsequently demonstrate how the proposed hybrid tendon and magnetic actuation approach enables enhanced workspace access when compared to a fixed-length design, improving access within simple and more complex aneurysm phantoms.

University of Leeds (GB)
Engineering and Physical Sciences Research Council, European Research Council, Leeds Biomedical Research Centre
Openalex Percentile: Top 6%
Intracranial Aneurysms: Treatment and Complications
4.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

3D-Printed Variable-Length Magnetically Steered Catheter Tip for Enhanced Access in Aneurysm Interventions — James H. Chandler, Pietro Valdastri, et al. · (2025) | TGRS Research Map | TGRS