Heat Transfer Characteristic Analysis of Double Pipe Heat Exchanger With A Continuous Helical Baffle By Numerical Analysis

In this paper, Three-dimensional computational fluid dynamics (CFD) simulations have been performed to study the annulus side laminar flow distribution, heat transfer characteristic, and pressure drop. This paper shows the effect of Reynolds number (Re), helical pitch and baffle height on Nusselt number (Nu), heat transfer coefficient, heat transfer rate, effectiveness & pressure drop of a double pipe heat exchanger with or without a continuous helical baffle. There are eight geometry was drawn by the design modeler such as pitch 102 mm, pitch 128mm, pitch 170mm, pitch 210mm, pitch 250mm with the pitch height 5mm & again for the pitch 102mm, spiral height 7mm, height 9mm, height 11mm. The outer diameter of the inner tube & inner diameter of the outer tube is fixed in all cases. The spiral was drawn 250 mm far from the inlet because the flow is fully developed after 250 mm. The inner pipe's outer surface is kept at a constant temperature of 340k. The temperature of the cold fluid is 293K. The outer tube’s the outside wall is kept adiabatic. The fully developed laminar flow passes through the annulus side with Reynolds numbers vary 700 to 1500.When the increases the pitch of the helical the Nusselt decreases. On the other hand, the Nusselt number increase while increasing helical height. If the comparison will take place between plain tube and helical tube the 78.53 % Nusselt number increases while using helical baffle for the pitch 102 mm & Reynolds number 1500. While using pitch 102 mm with a height of 11 mm instead of a plain tube the Nusselt number increases by 133.89 % for the Reynolds number 1500.When the increases the pitch of the helical the effectiveness decreases. On the other hand, the effectiveness increase while increasing helical height. When the increases the pitch of the helical the pressure drop decreases. On the other hand, the pressure drop increase while increasing helical height.

Authors

Institutions

Publication Details

Journal
SciEn Conference Series Engineering
Published
2025-05-07
DOI
https://doi.org/10.38032/scse.2025.1.12
Citations
1
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.71
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heat Transfer Characteristic Analysis of Double Pipe Heat Exchanger With A Continuous Helical Baffle By Numerical Analysis

M. A. Hafiz Mia, M. Inam
1 citations
SciEn Conference Series Engineering
Heat Transfer and Optimization
0.71
article

Heat Transfer Characteristic Analysis of Double Pipe Heat Exchanger With A Continuous Helical Baffle By Numerical Analysis

M. A. Hafiz Mia, M. Inam
article en
1 citations

Abstract

In this paper, Three-dimensional computational fluid dynamics (CFD) simulations have been performed to study the annulus side laminar flow distribution, heat transfer characteristic, and pressure drop. This paper shows the effect of Reynolds number (Re), helical pitch and baffle height on Nusselt number (Nu), heat transfer coefficient, heat transfer rate, effectiveness & pressure drop of a double pipe heat exchanger with or without a continuous helical baffle. There are eight geometry was drawn by the design modeler such as pitch 102 mm, pitch 128mm, pitch 170mm, pitch 210mm, pitch 250mm with the pitch height 5mm & again for the pitch 102mm, spiral height 7mm, height 9mm, height 11mm. The outer diameter of the inner tube & inner diameter of the outer tube is fixed in all cases. The spiral was drawn 250 mm far from the inlet because the flow is fully developed after 250 mm. The inner pipe's outer surface is kept at a constant temperature of 340k. The temperature of the cold fluid is 293K. The outer tube’s the outside wall is kept adiabatic. The fully developed laminar flow passes through the annulus side with Reynolds numbers vary 700 to 1500.When the increases the pitch of the helical the Nusselt decreases. On the other hand, the Nusselt number increase while increasing helical height. If the comparison will take place between plain tube and helical tube the 78.53 % Nusselt number increases while using helical baffle for the pitch 102 mm & Reynolds number 1500. While using pitch 102 mm with a height of 11 mm instead of a plain tube the Nusselt number increases by 133.89 % for the Reynolds number 1500.When the increases the pitch of the helical the effectiveness decreases. On the other hand, the effectiveness increase while increasing helical height. When the increases the pitch of the helical the pressure drop decreases. On the other hand, the pressure drop increase while increasing helical height.

SciEn Conference Series EngineeringVol. 1
Khulna University of Engineering and Technology (BD)
Openalex Percentile: Top 32%
Heat Transfer and Optimization
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Heat Transfer Characteristic Analysis of Double Pipe Heat Exchanger With A Continuous Helical Baffle By Numerical Analysis — M. A. Hafiz Mia, M. Inam · SciEn Conference Series Engineering (2025) | TGRS Research Map | TGRS