Comparison of Maklakov tonometry (10 grams) and corneal compensated intraocular pressure

Background Traditional Maklakoff tonometry does not take into account individual biomechanical properties of the eye, relying on average rigidity values ​​measured in vitro. In contrast, corneal compensated IOPcc, measured by bidirectional applanation, takes these individual characteristics into account and has been shown in the literature to be of greater diagnostic value in glaucoma [1–3]. Comparison of Maklakoff and IOPcc tonometry values ​​in the same patient population may change our understanding of the value of tonometers. Objective To determine IOPcc ranges corresponding to specific Maklakoff tonometry values ​​(with a 10-gram weight) in a sufficient number of patients, and to study the relationship between the Maklakoff indentation diameter and intraocular pressure, taking into account individual differences in corneal biomechanical properties [4, 5]. Material and methods A prospective comparative analysis included data from 14,440 eyes of 7,220 patients (mean age 60.1 ± 10.8 years) with primary open-angle glaucoma (POAG) or suspected glaucoma. The intraocular pressure values ​​obtained by Maklakov tonometry using a 10 g weight were compared with corneal-compensated intraocular pressure (IOPcc). Inclusion criteria were: the presence of a high-quality corneogram and IOPcc values ​​in the range from 6 to 35 mmHg. The diameter of the applanation print was measured with a caliper with an accuracy of 0.1 mm in accordance with the recommendations of the tonometer manufacturer. Results Variability in ocular structure affects IOP readings with the same print size after tonometry. A nomogram of IOPcc and print size correspondence was created for the Maklakov tonometer (10 g). The equation IOP=4.14×D2 -62.4×D+248 can serve as a calibration formula for accurate measurements in the middle and lower ranges of ophthalmotonus. Conclusion The Maklakov tonometer readings (10 g) allow determining the probable range of the patient's true intraocular pressure. This approach increases the value of conventional tonometry when it is impossible to more accurately assess the biomechanics of the eye. Key words: glaucoma; Maklakov tonometry; corneal-compensated pressure

Authors

Publication Details

Journal
Modern technologies in ophtalmology
Published
2025-05-14
DOI
https://doi.org/10.25276/2312-4911-2025-2-25-26
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Maklakov tonometry (10 grams) and corneal compensated intraocular pressure

V S Zinina, A.A. Antonov, A.Y. Rogova
Modern technologies in ophtalmology
Glaucoma and retinal disorders
article

Comparison of Maklakov tonometry (10 grams) and corneal compensated intraocular pressure

V S Zinina, A.A. Antonov, A.Y. Rogova
article en

Abstract

Background Traditional Maklakoff tonometry does not take into account individual biomechanical properties of the eye, relying on average rigidity values ​​measured in vitro. In contrast, corneal compensated IOPcc, measured by bidirectional applanation, takes these individual characteristics into account and has been shown in the literature to be of greater diagnostic value in glaucoma [1–3]. Comparison of Maklakoff and IOPcc tonometry values ​​in the same patient population may change our understanding of the value of tonometers. Objective To determine IOPcc ranges corresponding to specific Maklakoff tonometry values ​​(with a 10-gram weight) in a sufficient number of patients, and to study the relationship between the Maklakoff indentation diameter and intraocular pressure, taking into account individual differences in corneal biomechanical properties [4, 5]. Material and methods A prospective comparative analysis included data from 14,440 eyes of 7,220 patients (mean age 60.1 ± 10.8 years) with primary open-angle glaucoma (POAG) or suspected glaucoma. The intraocular pressure values ​​obtained by Maklakov tonometry using a 10 g weight were compared with corneal-compensated intraocular pressure (IOPcc). Inclusion criteria were: the presence of a high-quality corneogram and IOPcc values ​​in the range from 6 to 35 mmHg. The diameter of the applanation print was measured with a caliper with an accuracy of 0.1 mm in accordance with the recommendations of the tonometer manufacturer. Results Variability in ocular structure affects IOP readings with the same print size after tonometry. A nomogram of IOPcc and print size correspondence was created for the Maklakov tonometer (10 g). The equation IOP=4.14×D2 -62.4×D+248 can serve as a calibration formula for accurate measurements in the middle and lower ranges of ophthalmotonus. Conclusion The Maklakov tonometer readings (10 g) allow determining the probable range of the patient's true intraocular pressure. This approach increases the value of conventional tonometry when it is impossible to more accurately assess the biomechanics of the eye. Key words: glaucoma; Maklakov tonometry; corneal-compensated pressure

Modern technologies in ophtalmologyVol. 60(2)
Openalex Percentile: Top 79%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.