Assessment of the safety of wearing scleral rigid gas permeable lenses in keratoconus according to endothelial microscopy

Relevance It is known that one of the markers of normal functioning of the cornea is the state of its endothelial layer [1, 2]. Currently, the most accessible and safe method for assessing the state of the endothelium is endothelial microscopy. The issue of a detailed study of the state of the endothelial layer in keratoconus (KK) against the background of long-term wearing of scleral rigid gas-permeable lenses (SGPCL) is poorly studied today [3, 4]. Objective To study the state of the endothelial layer of the cornea in keratoconus against the background of long-term wearing of scleral rigid gas-permeable lenses. Material and methods Fifty patients (100 eyes) with KK of various stages according to Amsler (stage I - 28 eyes; stage II - 25 eyes; stage III - 29 eyes; stage IV - 8 eyes) were examined, for whom optical correction of SGPCL was selected. All patients underwent standard ophthalmological examination. The dynamics of the corneal endothelial layer condition was performed using endothelial microscopy SP-3000P (Topсon, Japan) before and after one year of wearing the SGCL. The following main parameters were determined: endothelial cell density (ECD, cells/mm2), average endothelial cell area (ACE, μm2), coefficient of variation (CV, %) and percentage of hexagonal cells (HEX, %). Results The average ECD before wearing lenses was 2551 ± 499 cells/mm2. ACE values ​​were 386.12 ± 81.8 cells/mm2. The coefficient of variation and percentage of hexagonal cells were 42.66 ± 13.2 and 52.87 ± 9.7%, respectively. After one year of wearing the SGCL, all indicators had statistically insignificant changes. The average value of the PEC decreased by 1.4% and amounted to 2517 ± 523 cells/mm2 (p = 0.218). The SPEC increased by 1.3% and amounted to 391.34 ± 96.7 cells/mm2 (p = 0.578). The coefficient of variation increased by 3.5% and was equal to 44.21 ± 13.6% (p = 0.086), and the percentage of hexagonal cells decreased by 2% and amounted to 51.84 ± 10.6% (p = 0.477). Conclusion Thus, the obtained data allow us to conclude that the quantitative and qualitative indicators of the state of the endothelial layer of the cornea before and after a year of wearing the SJGCL in patients with CC do not differ significantly from each other, which indicates the safety of using lenses of this type in keratectasia. Key words: keratoconus; scleral rigid gas-permeable lenses; endothelial microscopy

Authors

Publication Details

Journal
Modern technologies in ophtalmology
Published
2025-05-14
DOI
https://doi.org/10.25276/2312-4911-2025-2-217-218
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of the safety of wearing scleral rigid gas permeable lenses in keratoconus according to endothelial microscopy

A.V. Kobzeva, G A Osipyan, M.N. Narbut, V.V. Averich
Modern technologies in ophtalmology
Corneal surgery and disorders
article

Assessment of the safety of wearing scleral rigid gas permeable lenses in keratoconus according to endothelial microscopy

A.V. Kobzeva, G A Osipyan, M.N. Narbut, V.V. Averich
article en

Abstract

Relevance It is known that one of the markers of normal functioning of the cornea is the state of its endothelial layer [1, 2]. Currently, the most accessible and safe method for assessing the state of the endothelium is endothelial microscopy. The issue of a detailed study of the state of the endothelial layer in keratoconus (KK) against the background of long-term wearing of scleral rigid gas-permeable lenses (SGPCL) is poorly studied today [3, 4]. Objective To study the state of the endothelial layer of the cornea in keratoconus against the background of long-term wearing of scleral rigid gas-permeable lenses. Material and methods Fifty patients (100 eyes) with KK of various stages according to Amsler (stage I - 28 eyes; stage II - 25 eyes; stage III - 29 eyes; stage IV - 8 eyes) were examined, for whom optical correction of SGPCL was selected. All patients underwent standard ophthalmological examination. The dynamics of the corneal endothelial layer condition was performed using endothelial microscopy SP-3000P (Topсon, Japan) before and after one year of wearing the SGCL. The following main parameters were determined: endothelial cell density (ECD, cells/mm2), average endothelial cell area (ACE, μm2), coefficient of variation (CV, %) and percentage of hexagonal cells (HEX, %). Results The average ECD before wearing lenses was 2551 ± 499 cells/mm2. ACE values ​​were 386.12 ± 81.8 cells/mm2. The coefficient of variation and percentage of hexagonal cells were 42.66 ± 13.2 and 52.87 ± 9.7%, respectively. After one year of wearing the SGCL, all indicators had statistically insignificant changes. The average value of the PEC decreased by 1.4% and amounted to 2517 ± 523 cells/mm2 (p = 0.218). The SPEC increased by 1.3% and amounted to 391.34 ± 96.7 cells/mm2 (p = 0.578). The coefficient of variation increased by 3.5% and was equal to 44.21 ± 13.6% (p = 0.086), and the percentage of hexagonal cells decreased by 2% and amounted to 51.84 ± 10.6% (p = 0.477). Conclusion Thus, the obtained data allow us to conclude that the quantitative and qualitative indicators of the state of the endothelial layer of the cornea before and after a year of wearing the SJGCL in patients with CC do not differ significantly from each other, which indicates the safety of using lenses of this type in keratectasia. Key words: keratoconus; scleral rigid gas-permeable lenses; endothelial microscopy

Modern technologies in ophtalmologyVol. 60(2)
Openalex Percentile: Top 81%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.