Experimental and Numerical Simulation Study on Fire Detection System for Ship Cable Tunnel
The response time of various fire detectors in the ship cable tunnel were studied by the open fire and smoldering experiments. The results show that the alarm sequence of fire detectors was linear temperature sensitive cable, aspirating smoke detector and spot type smoke detector. The FDS numerical simulation software was used to verify the experimental results under the same working conditions. The parameters of each fire detector sensor were set. This study can further improve the selection of fire detectors for ship cable tunnels.