Dielectric Ultra-focused Oscillatory (DUO) Monopolar Blade for Minimizing Thermal Damage in Electrosurgical Applications

With the widespread adoption of RF energy in electrosurgery, electrosurgery has become an essential element in most surgical procedures. In particular, monopolar electrodes, which are indispensable in most open surgeries, have been the subject of extensive studies focusing on electrode shape, material, coating, as well as RF generator control and temperature and/or impedance sensing. In electrosurgery, which delivers thermal energy to tissue for cutting and coagulation, heat represents both the most critical benefit and the greatest risk. The high operating temperatures of electrodes (exceeding 250°C), designed for efficiency as surgical tools, are known to cause excessive thermal damage to tissues and implanted devices. This paper proposes a novel blade-type monopolar electrode technology that employs highly focused dielectric heating as its energy transfer mechanism, in contrast to conventional monopolar electrode devices, which rely on ohmic loss and heat transfer at the contact surface between tissue and electrode. The proposed Dielectric Ultra-focused Oscillatory (DUO) blade is based on dielectric heating, enabling direct heating of tissue moisture without generating heat on the electrode itself. This approach inherently limits the temperature to 100°C due to the principles of water vaporization. This reduces thermal damage in tissue by more than 50% compared to conventional devices and offers the advantage of preventing physical damage to implanted devices within the patient's body, such as pacemakers, leads, and batteries. The advantages of the proposed DUO blade technology were validated through in-vivo and ex-vivo tests, demonstrating its superior performance compared to existing products.

Authors

Institutions

Publication Details

Published
2025-02-27
DOI
https://doi.org/10.1109/icbea66055.2025.00018
Citations
1
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dielectric Ultra-focused Oscillatory (DUO) Monopolar Blade for Minimizing Thermal Damage in Electrosurgical Applications

Eun-Soo Lee, Bo H. Choi, I J Choi, J. W. Heo
1 citations
Thyroid and Parathyroid Surgery
2.01
article

Dielectric Ultra-focused Oscillatory (DUO) Monopolar Blade for Minimizing Thermal Damage in Electrosurgical Applications

Eun-Soo Lee, Bo H. Choi, I J Choi, J. W. Heo
article en
1 citations

Abstract

With the widespread adoption of RF energy in electrosurgery, electrosurgery has become an essential element in most surgical procedures. In particular, monopolar electrodes, which are indispensable in most open surgeries, have been the subject of extensive studies focusing on electrode shape, material, coating, as well as RF generator control and temperature and/or impedance sensing. In electrosurgery, which delivers thermal energy to tissue for cutting and coagulation, heat represents both the most critical benefit and the greatest risk. The high operating temperatures of electrodes (exceeding 250°C), designed for efficiency as surgical tools, are known to cause excessive thermal damage to tissues and implanted devices. This paper proposes a novel blade-type monopolar electrode technology that employs highly focused dielectric heating as its energy transfer mechanism, in contrast to conventional monopolar electrode devices, which rely on ohmic loss and heat transfer at the contact surface between tissue and electrode. The proposed Dielectric Ultra-focused Oscillatory (DUO) blade is based on dielectric heating, enabling direct heating of tissue moisture without generating heat on the electrode itself. This approach inherently limits the temperature to 100°C due to the principles of water vaporization. This reduces thermal damage in tissue by more than 50% compared to conventional devices and offers the advantage of preventing physical damage to implanted devices within the patient's body, such as pacemakers, leads, and batteries. The advantages of the proposed DUO blade technology were validated through in-vivo and ex-vivo tests, demonstrating its superior performance compared to existing products.

Hanyang University (KR)
Openalex Percentile: Top 15%
Thyroid and Parathyroid Surgery
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Dielectric Ultra-focused Oscillatory (DUO) Monopolar Blade for Minimizing Thermal Damage in Electrosurgical Applications — Eun-Soo Lee, Bo H. Choi, et al. · (2025) | TGRS Research Map | TGRS