Research on Calibration Method and Uncertainty Evaluation of Pacemaker Analyzers

External pacemakers, also known as temporary pacemakers, have been widely used in clinical settings, significantly reducing patient mortality rates. Pacemaker analyzers are utilized to measure the parameters of pacemakers, ensuring their accuracy, as these parameters are critical to patient safety. Regular calibration is essential since pacemaker analyzers have been widely used. However, measurement institutions and published measurement standards rarely focus on the calibration of pacemaker analyzers. This paper designs a calibration method that uses a digital multimeter and a waveform generator to calibrate parameters such as internal resistance, current amplitude, pulse width, rate, and energy of the pacemaker analyzer. A program by C# in Visual Studio is developed to control the calibration instruments, therefore improving measurement efficiency. At the end of the paper, uncertainty evaluation of the calibration results is conducted.

Authors

Institutions

Publication Details

Published
2025-03-21
DOI
https://doi.org/10.1109/iscait64916.2025.11010312
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Calibration Method and Uncertainty Evaluation of Pacemaker Analyzers

Yunling Wang, Jianqiang Gao, Lei Yu
Muscle activation and electromyography studies
article

Research on Calibration Method and Uncertainty Evaluation of Pacemaker Analyzers

Yunling Wang, Jianqiang Gao, Lei Yu
article en

Abstract

External pacemakers, also known as temporary pacemakers, have been widely used in clinical settings, significantly reducing patient mortality rates. Pacemaker analyzers are utilized to measure the parameters of pacemakers, ensuring their accuracy, as these parameters are critical to patient safety. Regular calibration is essential since pacemaker analyzers have been widely used. However, measurement institutions and published measurement standards rarely focus on the calibration of pacemaker analyzers. This paper designs a calibration method that uses a digital multimeter and a waveform generator to calibrate parameters such as internal resistance, current amplitude, pulse width, rate, and energy of the pacemaker analyzer. A program by C# in Visual Studio is developed to control the calibration instruments, therefore improving measurement efficiency. At the end of the paper, uncertainty evaluation of the calibration results is conducted.

Shanghai Institute of Measurement and Testing Technology (CN)
Openalex Percentile: Top 88%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on Calibration Method and Uncertainty Evaluation of Pacemaker Analyzers — Yunling Wang, Jianqiang Gao, et al. · (2025) | TGRS Research Map | TGRS