Analysis and Improvement of Measurement Accuracy of Insertion Loss

With the development of communication technology, more and more products need to measure the insertion loss, so it is more and more important to measure the loss value accurately. Occasionally, resonance, interference and jitter will occur in the measurement, which will lead to abnormal results, and the measurement value deviates from the linear law of the target at a single frequency, PCB design and measurement workers often bring serious confusion. In order to measure the design and measurement accuracy more accurately, this paper mainly aims at the difference between the long and short lines (X2-X1) in DELTA-L measurement method, the difference between Delta-L 3.0 and Delta-L 4.0, and the influence of back drilling on resonance, the accuracy of far-end and near-end via measurement, and the influence of pitch distance between lines on Set2dil measurement. It is found that Delta-L measurement with X2-X1≥5inch, increasing back drill and using Delta-L 4.0 can improve the measurement accuracy.

Authors

Publication Details

Published
2025-03-24
DOI
https://doi.org/10.1109/cstic64481.2025.11018014
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Improvement of Measurement Accuracy of Insertion Loss

Fanhong, Chenyong, Hezixiu, Chen Wuyong et al.
Engineering Applied Research
article

Analysis and Improvement of Measurement Accuracy of Insertion Loss

Fanhong, Chenyong, Hezixiu, Chen Wuyong, Songbo, Xierongde
article en

Abstract

With the development of communication technology, more and more products need to measure the insertion loss, so it is more and more important to measure the loss value accurately. Occasionally, resonance, interference and jitter will occur in the measurement, which will lead to abnormal results, and the measurement value deviates from the linear law of the target at a single frequency, PCB design and measurement workers often bring serious confusion. In order to measure the design and measurement accuracy more accurately, this paper mainly aims at the difference between the long and short lines (X2-X1) in DELTA-L measurement method, the difference between Delta-L 3.0 and Delta-L 4.0, and the influence of back drilling on resonance, the accuracy of far-end and near-end via measurement, and the influence of pitch distance between lines on Set2dil measurement. It is found that Delta-L measurement with X2-X1≥5inch, increasing back drill and using Delta-L 4.0 can improve the measurement accuracy.

Openalex Percentile: Top 87%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.