A High-Sensitivity Frequency Counter for Free-Induction-Decay Signals

Real-time frequency readout of time-dependent pulsed signals with a high sensitivity are key elements in many applications using atomic devices, such as FID atomic magnetometers. In this paper, we propose a frequency measurement algorithm based on the Hilbert transform and implement such a scheme in a FPGA-based frequency counter. By testing pulsed exponential-decay oscillation signals in the frequency range of 10 to 500 kHz, this frequency counter shows a frequency sensitivity better than 100 μHz/ √ Hz at 10 Hz, with an output rate of 200 Hz. When the output rate is increased to 1000 Hz, the sensitivity remains better than 400 μHz/ √ Hz at 10 Hz. The performance on frequency sensitivity is comparable with results obtained by off-line nonlinear fitting processes. In addition, this frequency counter does not require the pre-knowledge of the analytic expression of the input signals. The realization of such a device paves the way for practical applications of highly-sensitive FID atomic magnetometers..

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3575977
Citations
1
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High-Sensitivity Frequency Counter for Free-Induction-Decay Signals

Yesu Feng, D. Sheng, Yiren Li, Mingrui Shu et al.
1 citations
IEEE Transactions on Instrumentation and Measurement
Advanced Electrical Measurement Techniques
0.73
article

A High-Sensitivity Frequency Counter for Free-Induction-Decay Signals

Yesu Feng, D. Sheng, Yiren Li, Mingrui Shu, Xinjun Hao, Yuming Wang, Kai Liu, He Jiang, Tae-Hyeon Gong
article en
1 citations

Abstract

Real-time frequency readout of time-dependent pulsed signals with a high sensitivity are key elements in many applications using atomic devices, such as FID atomic magnetometers. In this paper, we propose a frequency measurement algorithm based on the Hilbert transform and implement such a scheme in a FPGA-based frequency counter. By testing pulsed exponential-decay oscillation signals in the frequency range of 10 to 500 kHz, this frequency counter shows a frequency sensitivity better than 100 μHz/ √ Hz at 10 Hz, with an output rate of 200 Hz. When the output rate is increased to 1000 Hz, the sensitivity remains better than 400 μHz/ √ Hz at 10 Hz. The performance on frequency sensitivity is comparable with results obtained by off-line nonlinear fitting processes. In addition, this frequency counter does not require the pre-knowledge of the analytic expression of the input signals. The realization of such a device paves the way for practical applications of highly-sensitive FID atomic magnetometers..

IEEE Transactions on Instrumentation and MeasurementVol. 74
University of Science and Technology of China (CN), Wuhan Ship Development & Design Institute (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 28%
Advanced Electrical Measurement Techniques
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.