Predeployment Calibration Framework for Low-Cost Gas Sensors: An Adaptive Environmental Parameter Model
Reliable toxic gas detection is vital for residential and industrial safety. While precise sensors are expensive, affordable ones face challenges of non-linearity and environmental sensitivity, particularly from temperature (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$T$</tex-math></inline-formula>) and humidity (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$H$</tex-math></inline-formula>) effects. In this work we present a novel pre-deployment calibration framework that accounts for these environmental factors on the sensor behaviour, given by the resistance ratio (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$R_{s}/R_{o}$</tex-math></inline-formula>) at constant gas concentration levels. The proposed method first refines the baseline resistance (<inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$R_{s}$</tex-math></inline-formula>) estimation by fitting a power-law model to known gas concentrations, then applies a cubic regression model to capture the non-linear effects of temperature and humidity on the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$R_{s}/R_{o}$</tex-math></inline-formula> ratio. Cubic regression achieves superior accuracy (> 5.8%) over lower-order models while reducing over-fitting risks compared to higher-order polynomials. It achieves 99.65% average accuracy, outperforming the 96.73% from standard libraries. This improved performance is particularly notable at low ppm levels, where direct <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$R_{s}$</tex-math></inline-formula> measurements are typically noisy and unstable. The enhanced stability and accuracy of the proposed method were validated over a continuous 90-minute test period.
Authors
- A. J. Nelson
- Abhishek Srivastava (ORCID: https://orcid.org/0000-0003-3140-6137)
- S.P. Mehta
- Srikar Somanchi (ORCID: https://orcid.org/0009-0002-1828-1552)
- Inesh Dheer
Institutions
- International Institute of Information Technology, Hyderabad (IN)
Publication Details
- Journal
- IEEE Sensors Letters
- Published
- 2025-06-03
- DOI
- https://doi.org/10.1109/lsens.2025.3576152
- Citations
- 1
- Primary Topic
- Air Quality Monitoring and Forecasting
- Type
- article
- Field-Weighted Citation Impact
- 0.80