Characterization of non-Gaussian beam profiles using laser ablation

We characterized fluence distributions [J/cm2] of focused non-Gaussian laser beams using the ablation imprints method. This method is derived from the Liu’s method that is commonly applied to measure beam widths of Gaussian laser beams and laser ablation threshold fluences of studied materials. However, Liu’s method can measure only Gaussian beams, which is often not the case in experiments. The ablation imprints method can characterize non-Gaussian beam with high dynamic range (≈ 10-3). Therefore, we accurately evaluate the fraction of the pulse energy contained in low-fluence beam tails which increases the accuracy of the peak fluence determination. We show two examples of the measurement. One at PALS laser (Vis) in comparison with far-field imaging, and the other at the European XFEL for grazing incidence LIDT measurement at 1 keV.

Authors

Institutions

Publication Details

Published
2025-06-03
DOI
https://doi.org/10.1117/12.3058273
Primary Topic
Advanced Measurement and Metrology Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of non-Gaussian beam profiles using laser ablation

Vojtěch Vozda, J. Chalupský, V. Hájková, Mikako Makita et al.
Advanced Measurement and Metrology Techniques
article

Characterization of non-Gaussian beam profiles using laser ablation

Vojtěch Vozda, J. Chalupský, V. Hájková, Mikako Makita, M. Krupka, Jan Wild, L. Juha, J. Dostál, Maurizio Vannoni, Šimon Jelínek, Marziyeh Tavakkoly, T. Burian, R. Dudžák
article en

Abstract

We characterized fluence distributions [J/cm2] of focused non-Gaussian laser beams using the ablation imprints method. This method is derived from the Liu’s method that is commonly applied to measure beam widths of Gaussian laser beams and laser ablation threshold fluences of studied materials. However, Liu’s method can measure only Gaussian beams, which is often not the case in experiments. The ablation imprints method can characterize non-Gaussian beam with high dynamic range (≈ 10-3). Therefore, we accurately evaluate the fraction of the pulse energy contained in low-fluence beam tails which increases the accuracy of the peak fluence determination. We show two examples of the measurement. One at PALS laser (Vis) in comparison with far-field imaging, and the other at the European XFEL for grazing incidence LIDT measurement at 1 keV.

Charles University (CZ), Czech Academy of Sciences, Institute of Plasma Physics (CZ), FZU ‒ Institute of Physics of the Academy of Sciences of the Czech Republic (CZ), European X-Ray Free-Electron Laser (DE)
Openalex Percentile: Top 88%
Advanced Measurement and Metrology Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Characterization of non-Gaussian beam profiles using laser ablation — Vojtěch Vozda, J. Chalupský, et al. · (2025) | TGRS Research Map | TGRS