Implementation and validation of a channelized hotelling observer model (CHO) in an AIFM task group: a national multicentric study in x-ray angiography (XA), a comprehensive and wide-reaching approach

This study aims to prove the feasibility of objectively characterizing clinical XA protocols by implementing a model observer. The model observer's performance aligns with a human observer's and is described using a simple and comprehensive figure of merit (FOM). The practical implications of this study, which utilized the Leeds TO10 phantom to acquire 146 imaging datasets in a fixed setup measuring kerma rate from four manufacturers and seven XA models by thirteen hospitals, are significant. The datasets were divided and analyzed into three main protocol categories (cardiac, neurological, and vascular) acquired with the field of view (FOV) locally used in that hospital. A 40-channel Gabor CHO was employed to analyze the datasets and calculate the contrast detail (CD) curves. A new figure of merit (FOM) tailored for the present task was calculated, accounting for image quality and kerma rate. The FOM demonstrated our observer model's ability to describe the XA protocol's optimization. Short-term reproducibility of selected XA protocols was within 10%. Smaller FOVs lowered long-term reproducibility in terms of FOM because the position of the dosimeter increasingly influenced the automatic exposure parameters. This study demonstrates the feasibility of using a CHO model observer to assess an angiography system's quality using a CD paradigm. The insights gained from this study will be instrumental in developing tolerance requirements for future quality assurance guides, enhancing the quality of X-ray angiography protocols, and improving patient care.

Authors

Institutions

Publication Details

Journal
Biomedical Physics & Engineering Express
Published
2025-06-03
DOI
https://doi.org/10.1088/2057-1976/addfdd
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementation and validation of a channelized hotelling observer model (CHO) in an AIFM task group: a national multicentric study in x-ray angiography (XA), a comprehensive and wide-reaching approach

V. Ravaglia, Domenico Lizio, O. Ortenzia, M. Quattrocchi et al.
Biomedical Physics & Engineering Express
Cardiac Imaging and Diagnostics
article

Implementation and validation of a channelized hotelling observer model (CHO) in an AIFM task group: a national multicentric study in x-ray angiography (XA), a comprehensive and wide-reaching approach

V. Ravaglia, Domenico Lizio, O. Ortenzia, M. Quattrocchi, Raffaella Soavi, A. D’Alessio, R. Villa, L. Noferini, F. Luraschi, M. Cavallari, D. Trevisan, Marco Bertolini, Laura Verzellesi, C. Ghetti, Nico Lanconelli, F. Pietrobon, Aldo Mazzilli, Chiara Ingraito, M.A. Gilio, Noemi Cucurachi, Mauro Iori, Loredana D’Ercole, Andrea Nitrosi, Valeria Trojani, Nicoletta Parruccini, A. Bruschi, S. Mazzocchi, Giovanna Venturi, Elena Cantoni
article en

Abstract

This study aims to prove the feasibility of objectively characterizing clinical XA protocols by implementing a model observer. The model observer's performance aligns with a human observer's and is described using a simple and comprehensive figure of merit (FOM). The practical implications of this study, which utilized the Leeds TO10 phantom to acquire 146 imaging datasets in a fixed setup measuring kerma rate from four manufacturers and seven XA models by thirteen hospitals, are significant. The datasets were divided and analyzed into three main protocol categories (cardiac, neurological, and vascular) acquired with the field of view (FOV) locally used in that hospital. A 40-channel Gabor CHO was employed to analyze the datasets and calculate the contrast detail (CD) curves. A new figure of merit (FOM) tailored for the present task was calculated, accounting for image quality and kerma rate. The FOM demonstrated our observer model's ability to describe the XA protocol's optimization. Short-term reproducibility of selected XA protocols was within 10%. Smaller FOVs lowered long-term reproducibility in terms of FOM because the position of the dosimeter increasingly influenced the automatic exposure parameters. This study demonstrates the feasibility of using a CHO model observer to assess an angiography system's quality using a CD paradigm. The insights gained from this study will be instrumental in developing tolerance requirements for future quality assurance guides, enhancing the quality of X-ray angiography protocols, and improving patient care.

Biomedical Physics & Engineering ExpressVol. 11(4)
Università degli Studi del Piemonte Orientale “Amedeo Avogadro” (IT), University of Parma (IT), University of Padua (IT), University of Milan (IT), Ospedale Santa Chiara (IT), Azienda Sanitaria Unità Locale di Reggio Emilia (IT), AULSS 2 Marca Trevigiana (IT), Azienda Unità Sanitaria Locale Della Romagna (IT), Provincia Autonoma di Trento (IT), Azienda Ospedaliera San Gerardo (IT), University Hospitals Parma Medical Center (US), Azienda Ospedaliero-Universitaria Careggi (IT), Azienda USL di Bologna (IT), Azienda Ospedaliero Universitaria Maggiore della Carita (IT), Istituto delle Scienze Neurologiche di Bologna (IT), Ospedale di Parma (IT), Policlinico San Matteo Fondazione (IT), Istituti di Ricovero e Cura a Carattere Scientifico (IT), Azienda Usl Toscana Centro (IT), Istituti Ospitalieri di Cremona (IT), University of Bologna (IT)
Partnerships for the goals
Openalex Percentile: Top 81%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.