Numerical study of spouting pulsation and gas inlet velocity variation in a rectangular spouted fluidized bed

Abstract Gas–particle flow in a spouted fluidized bed with rectangular geometry and pulsed inflow was numerically studied using a coupled CFD–DEM approach. The study investigated pulsed spouting at frequencies of 1, 4, and 10 Hz under different combinations of spout and background gas velocities. When background gas was present, pulsed inlet flow effectively reduced dead zones and improved particle circulation across all frequencies. At 10 Hz, the spouted fluidized bed showed a 12.81% increase in particle travel distance and a 55% reduction in dead zones. On the other hand, the removal of background gas created a poor performance with dead zones increasing from 0.5% to 7.7% of the particles. The effect of varying inlet velocity ratios of gases was also studied and revealed that appropriate gas distribution could improve the bed performance. The results generally demonstrate that pulsed flow in combination with suitable inlet velocity distribution is capable of improving the hydrodynamics of spouted fluidized beds without altering any geometry or total flow rate.

Authors

Institutions

Publication Details

Journal
Engineering Research Express
Published
2025-06-03
DOI
https://doi.org/10.1088/2631-8695/ade02a
Primary Topic
Granular flow and fluidized beds
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical study of spouting pulsation and gas inlet velocity variation in a rectangular spouted fluidized bed

Maysam Saidi, Pedram Ghaderi Dehrash
Engineering Research Express
Granular flow and fluidized beds
article

Numerical study of spouting pulsation and gas inlet velocity variation in a rectangular spouted fluidized bed

Maysam Saidi, Pedram Ghaderi Dehrash
article en

Abstract

Abstract Gas–particle flow in a spouted fluidized bed with rectangular geometry and pulsed inflow was numerically studied using a coupled CFD–DEM approach. The study investigated pulsed spouting at frequencies of 1, 4, and 10 Hz under different combinations of spout and background gas velocities. When background gas was present, pulsed inlet flow effectively reduced dead zones and improved particle circulation across all frequencies. At 10 Hz, the spouted fluidized bed showed a 12.81% increase in particle travel distance and a 55% reduction in dead zones. On the other hand, the removal of background gas created a poor performance with dead zones increasing from 0.5% to 7.7% of the particles. The effect of varying inlet velocity ratios of gases was also studied and revealed that appropriate gas distribution could improve the bed performance. The results generally demonstrate that pulsed flow in combination with suitable inlet velocity distribution is capable of improving the hydrodynamics of spouted fluidized beds without altering any geometry or total flow rate.

Engineering Research ExpressVol. 7(3)
Razi University (IR)
Openalex Percentile: Top 87%
Granular flow and fluidized beds
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.