Test-retest and intrasession reliability of assisted sprint outcome measurements using a motorized resistance device

The aim of this study was to determine reliability of assisted sprint outcome measurements using a motorized resistance device (MRD). A total of 21 participants (16 males and 5 females; age 22.3 ± 3.9 years, body mass 75.2 ± 6.9 kg, height 177.9 ± 6.8 cm) completed two assisted sprint tests on four different test sessions while exposed to an external load (3 kg) provided by the MRD. Outcome variables included time, top speed, maximum acceleration and 5 m split times and speeds. Intrasession and test-retest reliability was assessed using intraclass correlation coefficient (ICC), coefficient of variation (CV), typical error (TE), smallest worthwhile (SWC) and moderate worthwhile change (MDC). For test-retest reliability mostly high to extremely high ICC values (>0.77), and good (<5%) CV values were observed for all outcome measurements. Specifically, all outcome measurements showed high to extremely high relative reliability (ICC ≥ 0.95) except 0-5 m time (0.86) and maximum acceleration (0.77). Good absolute reliability was observed for all outcome measurements (CV range: 0.9-3.7) except maximum acceleration (8.7). Furthermore, most outcome variables were rated as good and ok for SWC. Similar findings were observed for intrasession reliability with very high ICC values for all outcome measurements except maximum acceleration (0.85-0.93) and 0-5 time for session 2-4 (0.88-0.92). Similarly, CV was good for all outcome measurements for all sessions except maximum acceleration (5.7-5.9%). In addition, all outcome measurements had good to ok SWC, except for maximum acceleration. In conclusion, the present study shows that the MRD can obtain reliable assisted sprint outcome measurements and thereby provide coaches and researchers with new opportunities to advance, monitor and evaluate sprint training.

Authors

Institutions

Publication Details

Journal
Frontiers in Sports and Active Living
Published
2025-06-02
DOI
https://doi.org/10.3389/fspor.2025.1592707
Citations
2
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
3.44
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test-retest and intrasession reliability of assisted sprint outcome measurements using a motorized resistance device

Ola Eriksrud, Frederic Westheim
2 citations
Frontiers in Sports and Active Living
Sports Performance and Training
3.44
article

Test-retest and intrasession reliability of assisted sprint outcome measurements using a motorized resistance device

Ola Eriksrud, Frederic Westheim
article en
2 citations

Abstract

The aim of this study was to determine reliability of assisted sprint outcome measurements using a motorized resistance device (MRD). A total of 21 participants (16 males and 5 females; age 22.3 ± 3.9 years, body mass 75.2 ± 6.9 kg, height 177.9 ± 6.8 cm) completed two assisted sprint tests on four different test sessions while exposed to an external load (3 kg) provided by the MRD. Outcome variables included time, top speed, maximum acceleration and 5 m split times and speeds. Intrasession and test-retest reliability was assessed using intraclass correlation coefficient (ICC), coefficient of variation (CV), typical error (TE), smallest worthwhile (SWC) and moderate worthwhile change (MDC). For test-retest reliability mostly high to extremely high ICC values (>0.77), and good (<5%) CV values were observed for all outcome measurements. Specifically, all outcome measurements showed high to extremely high relative reliability (ICC ≥ 0.95) except 0-5 m time (0.86) and maximum acceleration (0.77). Good absolute reliability was observed for all outcome measurements (CV range: 0.9-3.7) except maximum acceleration (8.7). Furthermore, most outcome variables were rated as good and ok for SWC. Similar findings were observed for intrasession reliability with very high ICC values for all outcome measurements except maximum acceleration (0.85-0.93) and 0-5 time for session 2-4 (0.88-0.92). Similarly, CV was good for all outcome measurements for all sessions except maximum acceleration (5.7-5.9%). In addition, all outcome measurements had good to ok SWC, except for maximum acceleration. In conclusion, the present study shows that the MRD can obtain reliable assisted sprint outcome measurements and thereby provide coaches and researchers with new opportunities to advance, monitor and evaluate sprint training.

Frontiers in Sports and Active LivingVol. 7
Norwegian School of Sport Sciences (NO)
Openalex Percentile: Top 9%
Sports Performance and Training
3.44
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Test-retest and intrasession reliability of assisted sprint outcome measurements using a motorized resistance device — Ola Eriksrud, Frederic Westheim · Frontiers in Sports and Active Living (2025) | TGRS Research Map | TGRS