BEGAM, a new apparatus for the identification of β emitter contaminants in radiopharmaceuticals

The BEGAM project aims at developing a portable detector capable of performing γ/β coincidence and anti-coincidence measurements to estimate the presence of long-lived β-contaminants in radiopharmaceutical solutions. A preliminary prototype of the apparatus is under construction. It is composed of four sectors of Caesium Iodide (CsI) scintillators surrounding a cylindrical plastic scintillator. The scintillation readout is performed via silicon photomultiplier (SiPM) and after some preamplification the signals are sent to a commercial digitizer. Geant4 simulations of the detector's response have been developed and validated using gamma and electron sources. Preliminary γ/β coincidence measurements from a 207Bi source have been performed. Near-future plans include testing the BEGAM detector to estimate the activity of 99Mo contaminants in 99mTc solutions.

Authors

Institutions

Publication Details

Journal
HNPS Advances in Nuclear Physics
Published
2025-05-31
DOI
https://doi.org/10.12681/hnpsanp.8134
Primary Topic
Nuclear and radioactivity studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

BEGAM, a new apparatus for the identification of β emitter contaminants in radiopharmaceuticals

A. Nannini, S. Piantelli, P. Saletti, G. Casini et al.
HNPS Advances in Nuclear Physics
Nuclear and radioactivity studies
article

BEGAM, a new apparatus for the identification of β emitter contaminants in radiopharmaceuticals

A. Nannini, S. Piantelli, P. Saletti, G. Casini, M. Perri, Alessandro Passeri, Giulia Nicastro
article en

Abstract

The BEGAM project aims at developing a portable detector capable of performing γ/β coincidence and anti-coincidence measurements to estimate the presence of long-lived β-contaminants in radiopharmaceutical solutions. A preliminary prototype of the apparatus is under construction. It is composed of four sectors of Caesium Iodide (CsI) scintillators surrounding a cylindrical plastic scintillator. The scintillation readout is performed via silicon photomultiplier (SiPM) and after some preamplification the signals are sent to a commercial digitizer. Geant4 simulations of the detector's response have been developed and validated using gamma and electron sources. Preliminary γ/β coincidence measurements from a 207Bi source have been performed. Near-future plans include testing the BEGAM detector to estimate the activity of 99Mo contaminants in 99mTc solutions.

HNPS Advances in Nuclear Physics(S01)
Istituto Nazionale di Fisica Nucleare, Sezione di Firenze (IT)
Openalex Percentile: Top 86%
Nuclear and radioactivity studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.