Platelet Distribution Amplitude (PDW) and Mean Platelet Volume (MPV): two simple, practical and specific indicators of platelet activation in Liquid PRF

Background: platelet indices are potentially useful markers in diagnosing liquid PRF platelet activation and its quality. An increase both in mean platelet volume (MPV) and platelet distribution width (PDW) is due to platelet activation and comes from platelet enlargement and pseudopodia formation. Our hypothesis is that, using different vials and centrifuges to obtain liquid PRF, there might be different MPV and PDW values, which would point toward different type or level of activation. Methods: Platelet indices (MPV, PDW, MPV/Plt, PDW/Plt) were measured in different Liquid PRF types/groups. Five different types of Liquid PRF were prepared: Liquid Fibrinogen 2700 rpm × 3’ (820 g) (RCF clot=608 g; RCF max =816 g; RCF min =326 g); i-PRF 3300 rpm (1220 g) × 3’(RCF clot =765 g; RCF max = 1008 g; RCF min =403 g); i-PRF 700 rpm (55 g) × 5’(RCF clot =38 g; RCF max =55 g; RCF min =22 g); A-PRF 1300 rpm (189 g) × 5’(RCFclot=142 g; RCFmax=189 g; RCFmin=66 g); C-PRF 2500 rpm (700 g) × 8’ and also PRP (Platelet rich Plasma) [2200 rpm, (1147 g) x 20 min]. The studied hematological parameters were: platelet count (Plt), mean platelet volume (MPV) and platelet distribution width (PDW), as well as MPV/Plt ratio and PDW/Plt ratio. Results: the highest MPV found in Vacumed FL vials was of 9.428±0.69 fL, while in original S- PRF vials it was 9.56±0.77 fL p=0.49, whatever the type of centrifuge employed; highest PDW found in Vacumed FL vials was of 11.71±0.66 %, while with original S-PRF vials it was 11.7±1.95 % p=0.974, whatever the type of centrifuge employed. Hence no difference tied to the type of vial and centrifuge was found between obtained values, but only based on the type of Liquid PRF produced. Conclusions: PDW and MPV are the most specific markers for platelet activation, as they do not increase in values during simple platelet enlargement and their value is not related to the type of vial and centrifuge used, but only to the type of PRF produced.

Authors

Publication Details

Journal
Archives of Clinical and Biomedical Research
Published
2025-01-01
DOI
https://doi.org/10.26502/acbr.50170451
Primary Topic
Inflammatory Biomarkers in Disease Prognosis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Platelet Distribution Amplitude (PDW) and Mean Platelet Volume (MPV): two simple, practical and specific indicators of platelet activation in Liquid PRF

Giovanni Lepore, Francesco Crisci, Alessandro Crisci, Michela Crisci et al.
Archives of Clinical and Biomedical Research
Inflammatory Biomarkers in Disease Prognosis
article

Platelet Distribution Amplitude (PDW) and Mean Platelet Volume (MPV): two simple, practical and specific indicators of platelet activation in Liquid PRF

Giovanni Lepore, Francesco Crisci, Alessandro Crisci, Michela Crisci, Federica Feleppa, Fabiana Flagiello
article en

Abstract

Background: platelet indices are potentially useful markers in diagnosing liquid PRF platelet activation and its quality. An increase both in mean platelet volume (MPV) and platelet distribution width (PDW) is due to platelet activation and comes from platelet enlargement and pseudopodia formation. Our hypothesis is that, using different vials and centrifuges to obtain liquid PRF, there might be different MPV and PDW values, which would point toward different type or level of activation. Methods: Platelet indices (MPV, PDW, MPV/Plt, PDW/Plt) were measured in different Liquid PRF types/groups. Five different types of Liquid PRF were prepared: Liquid Fibrinogen 2700 rpm × 3’ (820 g) (RCF clot=608 g; RCF max =816 g; RCF min =326 g); i-PRF 3300 rpm (1220 g) × 3’(RCF clot =765 g; RCF max = 1008 g; RCF min =403 g); i-PRF 700 rpm (55 g) × 5’(RCF clot =38 g; RCF max =55 g; RCF min =22 g); A-PRF 1300 rpm (189 g) × 5’(RCFclot=142 g; RCFmax=189 g; RCFmin=66 g); C-PRF 2500 rpm (700 g) × 8’ and also PRP (Platelet rich Plasma) [2200 rpm, (1147 g) x 20 min]. The studied hematological parameters were: platelet count (Plt), mean platelet volume (MPV) and platelet distribution width (PDW), as well as MPV/Plt ratio and PDW/Plt ratio. Results: the highest MPV found in Vacumed FL vials was of 9.428±0.69 fL, while in original S- PRF vials it was 9.56±0.77 fL p=0.49, whatever the type of centrifuge employed; highest PDW found in Vacumed FL vials was of 11.71±0.66 %, while with original S-PRF vials it was 11.7±1.95 % p=0.974, whatever the type of centrifuge employed. Hence no difference tied to the type of vial and centrifuge was found between obtained values, but only based on the type of Liquid PRF produced. Conclusions: PDW and MPV are the most specific markers for platelet activation, as they do not increase in values during simple platelet enlargement and their value is not related to the type of vial and centrifuge used, but only to the type of PRF produced.

Archives of Clinical and Biomedical ResearchVol. 9(3)
Openalex Percentile: Top 81%
Inflammatory Biomarkers in Disease Prognosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.