Optimizing Attenuation Correction in 68Ga-PSMA PET Imaging Using Deep Learning and Artifact-Free Dataset Refinement

<b>Background/Objectives:</b> Attenuation correction (AC) is essential for achieving quantitatively accurate PET imaging. In <sup>68</sup>Ga-PSMA PET, however, artifacts such as respiratory motion, halo effects, and truncation errors in CT-based AC (CT-AC) images compromise image quality and impair model training for deep learning-based AC. This study proposes a novel artifact-refinement framework that filters out corrupted PET-CT images to create a clean dataset for training an image-domain AC model, eliminating the need for anatomical reference scans. <b>Methods:</b> A residual neural network (ResNet) was trained using paired PET non-AC and PET CT-AC images from a dataset of 828 whole-body <sup>68</sup>Ga-PSMA PET-CT scans. An initial model was trained using all data and employed to identify artifact-affected samples via voxel-level error metrics. These outliers were excluded, and the refined dataset was used to retrain the model with an L2 loss function. Performance was evaluated using metrics including mean error (ME), mean absolute error (MAE), relative error (RE%), RMSE, and SSIM on both internal and external test datasets. <b>Results:</b> The model trained with the artifact-free dataset demonstrated significantly improved performance: ME = -0.009 ± 0.43 SUV, MAE = 0.09 ± 0.41 SUV, and SSIM = 0.96 ± 0.03. Compared to the model trained on unfiltered data, the purified data model showed enhanced quantitative accuracy and robustness in external validation. <b>Conclusions:</b> The proposed data purification framework significantly enhances the performance of deep learning-based AC for <sup>68</sup>Ga-PSMA PET by mitigating artifact-induced errors. This approach facilitates reliable PET imaging in the absence of anatomical references, advancing clinical applicability and image fidelity.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-05-31
DOI
https://doi.org/10.3390/diagnostics15111400
Citations
1
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing Attenuation Correction in 68Ga-PSMA PET Imaging Using Deep Learning and Artifact-Free Dataset Refinement

Masoumeh Dorri Giv, Hossein Arabi, Emran Askari, Raheleh Tabari Juybari et al.
1 citations
Diagnostics
Medical Imaging Techniques and Applications
1.36
article

Optimizing Attenuation Correction in 68Ga-PSMA PET Imaging Using Deep Learning and Artifact-Free Dataset Refinement

Masoumeh Dorri Giv, Hossein Arabi, Emran Askari, Raheleh Tabari Juybari, Vahid Reza Dabbagh Kakhki, Sara Harsini, Nasrin Raeisi, Gülüzar Özbolat, Hossein Akbari‐Lalimi, Shahrokh Naseri, Ghasem Ali Divband, Somayeh Malmir, Vahid Roshan Ravan
article en
1 citations

Abstract

<b>Background/Objectives:</b> Attenuation correction (AC) is essential for achieving quantitatively accurate PET imaging. In <sup>68</sup>Ga-PSMA PET, however, artifacts such as respiratory motion, halo effects, and truncation errors in CT-based AC (CT-AC) images compromise image quality and impair model training for deep learning-based AC. This study proposes a novel artifact-refinement framework that filters out corrupted PET-CT images to create a clean dataset for training an image-domain AC model, eliminating the need for anatomical reference scans. <b>Methods:</b> A residual neural network (ResNet) was trained using paired PET non-AC and PET CT-AC images from a dataset of 828 whole-body <sup>68</sup>Ga-PSMA PET-CT scans. An initial model was trained using all data and employed to identify artifact-affected samples via voxel-level error metrics. These outliers were excluded, and the refined dataset was used to retrain the model with an L2 loss function. Performance was evaluated using metrics including mean error (ME), mean absolute error (MAE), relative error (RE%), RMSE, and SSIM on both internal and external test datasets. <b>Results:</b> The model trained with the artifact-free dataset demonstrated significantly improved performance: ME = -0.009 ± 0.43 SUV, MAE = 0.09 ± 0.41 SUV, and SSIM = 0.96 ± 0.03. Compared to the model trained on unfiltered data, the purified data model showed enhanced quantitative accuracy and robustness in external validation. <b>Conclusions:</b> The proposed data purification framework significantly enhances the performance of deep learning-based AC for <sup>68</sup>Ga-PSMA PET by mitigating artifact-induced errors. This approach facilitates reliable PET imaging in the absence of anatomical references, advancing clinical applicability and image fidelity.

DiagnosticsVol. 15(11)
Mashhad University of Medical Sciences (IR), Milad Hospital (IR), Terry Fox Research Institute (CA), Gonabad University of Medical Sciences (IR), University Hospital of Geneva (CH), Ghaem Hospital (IR), Payame Noor University (IR), Sinop University (TR)
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Industry, innovation and infrastructure
Openalex Percentile: Top 19%
Medical Imaging Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.