A Fiberglass-Cloth-Reinforced Perfluorosulfonic Acid Membrane

Perfluorosulfonic acid (PFSA) membranes have found broad-ranging applications, owing to their high ionic conductivity and excellent chemical stability. However, membranes with higher mechanical strength, lower area-specific resistance, reduced swelling, less gas crossover and more affordable costs are desirable. Herein, we report on the fabrication of a fiberglass-cloth-reinforced PFSA membrane using a simple solution cast method. The breaking strength of the reinforced membrane has the potential to reach 81 MPa, which is about 6 times and 2.5 times that of its non-reinforced counterpart and the commercial Nafion 117 (N117) membrane, respectively. The area swelling ratio of the reinforced membrane is lowered to merely 3%, which is only about 1/12 that of N117, in water at 100 °C. Despite ionic conduction being hindered by the fiberglass cloth, the reinforced PFSA membrane shows an area-specific resistance of only 0.069 Ω·cm<sup>2</sup>, which is 58% lower than that of N117, under 80 °C and 100% humidity. This research provides a promising technological pathway for the development of high-performance ionic conductive membranes.

Authors

Institutions

Publication Details

Journal
Membranes
Published
2025-06-02
DOI
https://doi.org/10.3390/membranes15060166
Citations
1
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fiberglass-Cloth-Reinforced Perfluorosulfonic Acid Membrane

Yuxin Wang, Yali Dou, Zhutao Zhang, Wen Zhang et al.
1 citations
Membranes
Fuel Cells and Related Materials
0.73
article

A Fiberglass-Cloth-Reinforced Perfluorosulfonic Acid Membrane

Yuxin Wang, Yali Dou, Zhutao Zhang, Wen Zhang, Li Xu
article en
1 citations

Abstract

Perfluorosulfonic acid (PFSA) membranes have found broad-ranging applications, owing to their high ionic conductivity and excellent chemical stability. However, membranes with higher mechanical strength, lower area-specific resistance, reduced swelling, less gas crossover and more affordable costs are desirable. Herein, we report on the fabrication of a fiberglass-cloth-reinforced PFSA membrane using a simple solution cast method. The breaking strength of the reinforced membrane has the potential to reach 81 MPa, which is about 6 times and 2.5 times that of its non-reinforced counterpart and the commercial Nafion 117 (N117) membrane, respectively. The area swelling ratio of the reinforced membrane is lowered to merely 3%, which is only about 1/12 that of N117, in water at 100 °C. Despite ionic conduction being hindered by the fiberglass cloth, the reinforced PFSA membrane shows an area-specific resistance of only 0.069 Ω·cm<sup>2</sup>, which is 58% lower than that of N117, under 80 °C and 100% humidity. This research provides a promising technological pathway for the development of high-performance ionic conductive membranes.

MembranesVol. 15(6)
Tianjin University (CN), State Key Laboratory of Chemical Engineering (CN)
Openalex Percentile: Top 28%
Fuel Cells and Related Materials
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Fiberglass-Cloth-Reinforced Perfluorosulfonic Acid Membrane — Yuxin Wang, Yali Dou, et al. · Membranes (2025) | TGRS Research Map | TGRS