EXPERIMENTAL RESEARCH ON REINFORCED CONCRETE SLABS WITH LOADS FROM COLUMN PLACED ON THE SLAB

Slabs made of reinforced concrete often get subjected to loads that are distributed uniformly across the whole surface of the slab. On the other hand, there are situations in which the slab is subjected to concentrated loads by columns that are put directly on the slab surface and located at the free edge of the slab. This can easily cause damage to the slab. The authors of this paper conducted an experimental investigation to examine the behavior of a reinforced concrete slab with dimensions of 1200×1600×120mm. The slab was subjected to direct column loads at the free edge of the slab. When the diameter of the primary load-bearing steel bars in the slab was changed, the findings of the research made it possible to establish the relationships between load-vertical displacement, load-tensile (compressive) deformation, and crack formation and propagation on the top and lower surfaces of the slab. Changing the steel bars resulted in a twenty percent decrease in load-bearing capacity for the S6 slab in comparison to the S1 slab, as demonstrated by the findings of the respective investigation.

Authors

Publication Details

Journal
JOURNAL OF MATERIALS & CONSTRUCTION
Published
2025-05-24
DOI
https://doi.org/10.54772/jomc.v15i01.926
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPERIMENTAL RESEARCH ON REINFORCED CONCRETE SLABS WITH LOADS FROM COLUMN PLACED ON THE SLAB

Lâm Thanh Quang Khải, Huynh Thi Kim Oanh
JOURNAL OF MATERIALS & CONSTRUCTION
Structural Behavior of Reinforced Concrete
article

EXPERIMENTAL RESEARCH ON REINFORCED CONCRETE SLABS WITH LOADS FROM COLUMN PLACED ON THE SLAB

Lâm Thanh Quang Khải, Huynh Thi Kim Oanh
article en

Abstract

Slabs made of reinforced concrete often get subjected to loads that are distributed uniformly across the whole surface of the slab. On the other hand, there are situations in which the slab is subjected to concentrated loads by columns that are put directly on the slab surface and located at the free edge of the slab. This can easily cause damage to the slab. The authors of this paper conducted an experimental investigation to examine the behavior of a reinforced concrete slab with dimensions of 1200×1600×120mm. The slab was subjected to direct column loads at the free edge of the slab. When the diameter of the primary load-bearing steel bars in the slab was changed, the findings of the research made it possible to establish the relationships between load-vertical displacement, load-tensile (compressive) deformation, and crack formation and propagation on the top and lower surfaces of the slab. Changing the steel bars resulted in a twenty percent decrease in load-bearing capacity for the S6 slab in comparison to the S1 slab, as demonstrated by the findings of the respective investigation.

JOURNAL OF MATERIALS & CONSTRUCTIONVol. 15(01)
Openalex Percentile: Top 88%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.