EXPERIMENTAL EVALUATION OF PERVIOUS CONCRETE DESIGNED BASED ON THE EXCESS PASTE THEORY: STRENGTH AND WATER PERMEABILITY

Urbanization increases impervious areas, requiring sustainable stormwater management like pervious concrete (PC). Standardized PC design methods are limited in Vietnam. This study evaluated the Excess Paste Theory, based on coating aggregates without filling voids to maintain permeability, for designing PC for pedestrian areas targeting ~40% void ratio and 7.5-10 MPa compressive strength. Experimental samples exhibited high interconnected porosity and efficient drainage. Average 7-day compressive strength was 8.5 MPa, meeting the target pedestrian traffic area. Variability was noted (manual mixing, lack of equipemnt for vibration and compaction of 10kPa for concrete), with failure in the cement paste layer. Initial results indicate the method's potential. Future work should enhance paste strength (e.g., via fine aggregate and/or reduced Dmax) for uniformity. PC design requires balancing porosity and strength

Authors

Publication Details

Journal
JOURNAL OF MATERIALS & CONSTRUCTION
Published
2025-02-28
DOI
https://doi.org/10.54772/jomc.v15i01.958
Primary Topic
Urban Stormwater Management Solutions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EXPERIMENTAL EVALUATION OF PERVIOUS CONCRETE DESIGNED BASED ON THE EXCESS PASTE THEORY: STRENGTH AND WATER PERMEABILITY

Phúc Lâm Đào
JOURNAL OF MATERIALS & CONSTRUCTION
Urban Stormwater Management Solutions
article

EXPERIMENTAL EVALUATION OF PERVIOUS CONCRETE DESIGNED BASED ON THE EXCESS PASTE THEORY: STRENGTH AND WATER PERMEABILITY

Phúc Lâm Đào
article en

Abstract

Urbanization increases impervious areas, requiring sustainable stormwater management like pervious concrete (PC). Standardized PC design methods are limited in Vietnam. This study evaluated the Excess Paste Theory, based on coating aggregates without filling voids to maintain permeability, for designing PC for pedestrian areas targeting ~40% void ratio and 7.5-10 MPa compressive strength. Experimental samples exhibited high interconnected porosity and efficient drainage. Average 7-day compressive strength was 8.5 MPa, meeting the target pedestrian traffic area. Variability was noted (manual mixing, lack of equipemnt for vibration and compaction of 10kPa for concrete), with failure in the cement paste layer. Initial results indicate the method's potential. Future work should enhance paste strength (e.g., via fine aggregate and/or reduced Dmax) for uniformity. PC design requires balancing porosity and strength

JOURNAL OF MATERIALS & CONSTRUCTIONVol. 15(01)
Openalex Percentile: Top 89%
Urban Stormwater Management Solutions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.