A Case Series of Valve‐in‐Valve Transcatheter Aortic Valve Replacement in Stentless Bioprosthetic Valves Using Self‐Expanding Platform With Minimalist Approach

Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR) has emerged as a valid treatment option in symptomatic patients with failed aortic bioprosthetic valves, most especially in those with intermediate, high or prohibitive risk of surgery. Due to the unique design of stentless bioprosthetic valves with absence of visible posts and stent frame, they present with challenges during ViV TAVR procedure. Our case series assessed the safety, feasibility, and early outcomes of ViV TAVR in patients with failed bioprosthetic aortic valve replacement (AVR) using self-expanding valve platform (Acurate Neo 2/AN2 valve) between March and September 2024 with minimalist approach. Procedural success, complications and early outcomes (mortality and functional status) were evaluated. A total number of three patients, mean age 75 ± 7 years, 67% female were included in the case series with high Society of Thoracic Surgeons (STS) and European System of Cardiac Operative Risk Evaluation II (EuroSCORE II) score. The mean time from initial surgery to ViV procedure was 18 ± 1 years. ViV procedure was successfully completed in all patients with no major complication, and no more than trivial trans/paravalvular regurgitation on discharge. There was no requirement for permanent pacemaker implantation, no stroke or mortality at 30-day and there was significant improvement in functional class alongside symptomatic improvement. We report our experience in ViV TAVR using AN2 valve in Shelhigh supra stentless aortic bioprosthesis and that this procedure despite anatomical and procedural challenges is feasible and safe.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2025-06-02
DOI
https://doi.org/10.1002/ccd.31625
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Case Series of Valve‐in‐Valve Transcatheter Aortic Valve Replacement in Stentless Bioprosthetic Valves Using Self‐Expanding Platform With Minimalist Approach

Elved Roberts, Adeogo Akinwale Olusan, Ján Kováč, Raj Rajendra
Catheterization and Cardiovascular Interventions
Cardiac Valve Diseases and Treatments
article

A Case Series of Valve‐in‐Valve Transcatheter Aortic Valve Replacement in Stentless Bioprosthetic Valves Using Self‐Expanding Platform With Minimalist Approach

Elved Roberts, Adeogo Akinwale Olusan, Ján Kováč, Raj Rajendra
article en

Abstract

Valve-in-valve (ViV) Transcatheter aortic valve replacement (TAVR) has emerged as a valid treatment option in symptomatic patients with failed aortic bioprosthetic valves, most especially in those with intermediate, high or prohibitive risk of surgery. Due to the unique design of stentless bioprosthetic valves with absence of visible posts and stent frame, they present with challenges during ViV TAVR procedure. Our case series assessed the safety, feasibility, and early outcomes of ViV TAVR in patients with failed bioprosthetic aortic valve replacement (AVR) using self-expanding valve platform (Acurate Neo 2/AN2 valve) between March and September 2024 with minimalist approach. Procedural success, complications and early outcomes (mortality and functional status) were evaluated. A total number of three patients, mean age 75 ± 7 years, 67% female were included in the case series with high Society of Thoracic Surgeons (STS) and European System of Cardiac Operative Risk Evaluation II (EuroSCORE II) score. The mean time from initial surgery to ViV procedure was 18 ± 1 years. ViV procedure was successfully completed in all patients with no major complication, and no more than trivial trans/paravalvular regurgitation on discharge. There was no requirement for permanent pacemaker implantation, no stroke or mortality at 30-day and there was significant improvement in functional class alongside symptomatic improvement. We report our experience in ViV TAVR using AN2 valve in Shelhigh supra stentless aortic bioprosthesis and that this procedure despite anatomical and procedural challenges is feasible and safe.

Catheterization and Cardiovascular InterventionsVol. 106(2)
University of Leicester (GB), Glenfield Hospital (GB)
Good health and well-being
Openalex Percentile: Top 78%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Case Series of Valve‐in‐Valve Transcatheter Aortic Valve Replacement in Stentless Bioprosthetic Valves Using Self‐Expanding Platform With Minimalist Approach — Elved Roberts, Adeogo Akinwale Olusan, et al. · Catheterization and Cardiovascular Interventions (2025) | TGRS Research Map | TGRS