Comparative computational and experimental insights into the structural, electrical, and biological properties of CeO2 fluorite ceramics

A comprehensive comparative study was conducted on synthesized (CS) and commercially procured (CP) cerium oxide (CeO₂) samples, and evaluating their computational, structural, microstructural, biocompatibility, and electrical properties. First-principles computational studies revealed that CS exhibited greater volume optimization than CP, although both samples demonstrated a band gap of 2.4–2.5 eV, consistent with the semiconducting nature of CeO₂. The density of states analysis indicated a strong hybridization between Ce-4f and O-2p orbitals, with CS, displaying enhanced electronic density near the Fermi level. X-ray diffraction studies followed by Rietveld refinement confirmed the fluorite structure. Microstructural analysis showed dense, agglomerated morphologies in both samples. However, CS exhibited a higher oxygen content than CP, implying variation in defect concentrations. FTIR confirmed phase purity with characteristic Ce–O vibrations at 435 and 1631 cm¹, while Raman spectroscopy supported this by revealing the F₂g mode (~ 465 cm¹) typical of fluorite-structured CeO₂. Electrical impedance spectroscopy revealed higher ionic conductivity in CS, with a lower grain boundary blocking factor (αgb = 0.42) compared to CP (αgb = 0.62), likely due to differences in defect density and microstructure. Biocompatibility tests showed that CeO₂-300 (CS) had the highest inhibitory efficacy (IC₅₀ ≈ 65.94 µg/ml), followed by CeO₂-800 (≈ 74.1 µg/ml) and CeO₂-Pure (CP) (≈ 86.88 µg/ml), indicating the influence of synthesis on biological response. These results highlight the critical impact of synthesis methods on the biocompatibility and electrical performance of CeO₂ materials useful as solid electrolyte in IT-SOFCs application.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-06-02
DOI
https://doi.org/10.1038/s41598-025-04843-2
Citations
16
Primary Topic
Electronic and Structural Properties of Oxides
Type
article
Field-Weighted Citation Impact
8.28

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative computational and experimental insights into the structural, electrical, and biological properties of CeO2 fluorite ceramics

Mohit Khosya, Upendra Kumar, Sangeeta Singh, Raj Kumar et al.
16 citations
Scientific Reports
Electronic and Structural Properties of Oxides
8.28
article

Comparative computational and experimental insights into the structural, electrical, and biological properties of CeO2 fluorite ceramics

Mohit Khosya, Upendra Kumar, Sangeeta Singh, Raj Kumar, V. K. Gupta
article en
16 citations

Abstract

A comprehensive comparative study was conducted on synthesized (CS) and commercially procured (CP) cerium oxide (CeO₂) samples, and evaluating their computational, structural, microstructural, biocompatibility, and electrical properties. First-principles computational studies revealed that CS exhibited greater volume optimization than CP, although both samples demonstrated a band gap of 2.4–2.5 eV, consistent with the semiconducting nature of CeO₂. The density of states analysis indicated a strong hybridization between Ce-4f and O-2p orbitals, with CS, displaying enhanced electronic density near the Fermi level. X-ray diffraction studies followed by Rietveld refinement confirmed the fluorite structure. Microstructural analysis showed dense, agglomerated morphologies in both samples. However, CS exhibited a higher oxygen content than CP, implying variation in defect concentrations. FTIR confirmed phase purity with characteristic Ce–O vibrations at 435 and 1631 cm¹, while Raman spectroscopy supported this by revealing the F₂g mode (~ 465 cm¹) typical of fluorite-structured CeO₂. Electrical impedance spectroscopy revealed higher ionic conductivity in CS, with a lower grain boundary blocking factor (αgb = 0.42) compared to CP (αgb = 0.62), likely due to differences in defect density and microstructure. Biocompatibility tests showed that CeO₂-300 (CS) had the highest inhibitory efficacy (IC₅₀ ≈ 65.94 µg/ml), followed by CeO₂-800 (≈ 74.1 µg/ml) and CeO₂-Pure (CP) (≈ 86.88 µg/ml), indicating the influence of synthesis on biological response. These results highlight the critical impact of synthesis methods on the biocompatibility and electrical performance of CeO₂ materials useful as solid electrolyte in IT-SOFCs application.

Scientific ReportsVol. 15(1)
Indian Institute of Information Technology Allahabad (IN), Indian Institute of Technology Delhi (IN)
Indian Institute of Information Technology, Allahabad, Science and Engineering Research Board
Openalex Percentile: Top 2%
Electronic and Structural Properties of Oxides
8.28
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.