Gambaran Kadar Perak (Ag) Pada Limbah Cair Fixer Di Instalasi Radiologi Rumah Sakit Pertamedika Ummi Rosnati Banda Aceh

A study on the description of silver (Ag) levels in liquid waste fixer originating from a radiology installation before being processed at the Waste Treatment Installation is sometimes necessary to avoid environmental pollution. The time and place of this research were conducted at the radiology installation for approximately 1 (one) month. The purpose of this writing is to determine the description of the silver (Ag) levels of fixer in the radiology installation. This research method is field observation. and the processing of silver levels was carried out at the Medan standardization research agency (baristand) with researchers sending samples of 100 mg/l to be tested for silver levels. The thing studied in this study was to determine the description of silver levels using the Atomic Absorption Spectrophotometry (AAS) method. From the observation results after processing, the Ag content was 0.03 mg/L. After processing, the silver content was allowed to be discharged directly into the environment or public channels because the results were still below the established quality standards, namely 5.0 mg/L. However, it would be better if each hospital was advised to process the liquid waste at the Wastewater Treatment Plant to avoid environmental pollution.

Authors

Institutions

Publication Details

Journal
Jurnal Mahasiswa Ilmu Kesehatan
Published
2024-10-30
DOI
https://doi.org/10.59841/jumkes.v2i4.2330
Primary Topic
Computer Science and Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gambaran Kadar Perak (Ag) Pada Limbah Cair Fixer Di Instalasi Radiologi Rumah Sakit Pertamedika Ummi Rosnati Banda Aceh

Dewi Febriyanti, Shama I. Y. Adam, Pocut Zairiana Finzia
Jurnal Mahasiswa Ilmu Kesehatan
Computer Science and Engineering
article

Gambaran Kadar Perak (Ag) Pada Limbah Cair Fixer Di Instalasi Radiologi Rumah Sakit Pertamedika Ummi Rosnati Banda Aceh

Dewi Febriyanti, Shama I. Y. Adam, Pocut Zairiana Finzia
article en

Abstract

A study on the description of silver (Ag) levels in liquid waste fixer originating from a radiology installation before being processed at the Waste Treatment Installation is sometimes necessary to avoid environmental pollution. The time and place of this research were conducted at the radiology installation for approximately 1 (one) month. The purpose of this writing is to determine the description of the silver (Ag) levels of fixer in the radiology installation. This research method is field observation. and the processing of silver levels was carried out at the Medan standardization research agency (baristand) with researchers sending samples of 100 mg/l to be tested for silver levels. The thing studied in this study was to determine the description of silver levels using the Atomic Absorption Spectrophotometry (AAS) method. From the observation results after processing, the Ag content was 0.03 mg/L. After processing, the silver content was allowed to be discharged directly into the environment or public channels because the results were still below the established quality standards, namely 5.0 mg/L. However, it would be better if each hospital was advised to process the liquid waste at the Wastewater Treatment Plant to avoid environmental pollution.

Jurnal Mahasiswa Ilmu KesehatanVol. 2(4)
Universitas Muhammadiyah Aceh (ID)
Openalex Percentile: Top 72%
Computer Science and Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.