Robotic Wound Closure: Detection and Control of Patient Motion

Physiological organ motion, such as breathing movement, presents a challenge in the development of medical robots for autonomous wound closure. The robot’s task is to determine the wound’s pose and relay magnetic fixtures near the wound edge with pre-specified accuracy. To address this problem, a visual motion detection system (VMDS) is designed to determine the pose of a wound. To ensure precise tracking of the wound, a varying target sliding mode control (VT-SMC) scheme was developed to follow the wound movement. Experiments demonstrate excellent agreement, with less than 0.67 mm variance between the VMDS measurements, real motion for three translations, and 0.26 degrees for three rotations. The relay error is 0.86 mm under the patient motion (position: 15 mm, orientation: 5 deg) in the autonomous robotic wound closure system. The developed robot successfully achieves the necessary motion tracking, which proves sufficient for the accuracy of wound closure in clinical applicability.

Authors

Institutions

Publication Details

Journal
Actuators
Published
2025-05-31
DOI
https://doi.org/10.3390/act14060274
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robotic Wound Closure: Detection and Control of Patient Motion

Edward H. Currie, Yizhang Zhao, Sina Y. Rabbany, Louis R. Kavoussi
Actuators
Soft Robotics and Applications
article

Robotic Wound Closure: Detection and Control of Patient Motion

Edward H. Currie, Yizhang Zhao, Sina Y. Rabbany, Louis R. Kavoussi
article en

Abstract

Physiological organ motion, such as breathing movement, presents a challenge in the development of medical robots for autonomous wound closure. The robot’s task is to determine the wound’s pose and relay magnetic fixtures near the wound edge with pre-specified accuracy. To address this problem, a visual motion detection system (VMDS) is designed to determine the pose of a wound. To ensure precise tracking of the wound, a varying target sliding mode control (VT-SMC) scheme was developed to follow the wound movement. Experiments demonstrate excellent agreement, with less than 0.67 mm variance between the VMDS measurements, real motion for three translations, and 0.26 degrees for three rotations. The relay error is 0.86 mm under the patient motion (position: 15 mm, orientation: 5 deg) in the autonomous robotic wound closure system. The developed robot successfully achieves the necessary motion tracking, which proves sufficient for the accuracy of wound closure in clinical applicability.

ActuatorsVol. 14(6)
Hofstra University (US), Long Island Jewish Medical Center (US)
Openalex Percentile: Top 89%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.