The Influence of Central Corneal Thickness on The Intraocular Pressure as Measured by Different Tonometers: Non-Contact Tonometer and Goldmann Applanation Tonometer

Background and objectives: Intraocular pressure plays a crucial role in maintaining vision and preventing eye disease. Beyond its importance in diagnosing and managing glaucoma, intraocular pressure measurements significantly impact the evaluation of postoperative outcomes, complications and optimize patient recovery. This study quantifies the influence of central corneal thickness on intraocular pressure using both Goldmann applanation tonometer and non-contact tonometer. Methods: In a prospective clinical trial, the subjects were recruited from glaucoma unit at Shahid Dr. Aso Eye Hospital in Sulaimania city/Iraq between January and June 2023. Intraocular pressure measurements were conducted in a randomized sequence for both eyes using both Goldmann applanation tonometry and non-contact tonometry exploring the correlation between measured inter-tonometer discrepancies employing linear regression analysis with central corneal thickness. Results: The study included 200 eyes of 100 consecutive patients diagnosed with either ocular hypertension or glaucoma. Mean age was 56.8 years, male (55%) and female (45%). Mean central corneal thickness was 533 ± 42 ?m and mean intra ocular pressure were 14.9 ± 4.3 mm Hg, 19.3 ± 5.4 mm Hg for Goldmann applanation tonometry and non-contact tonometry, respectively. There is a statistically significant relationship between central corneal thickness and intraocular pressure by Goldmann applanation tonometry (r2 = 0.1, p 0.001) and non-contact tonometry (r2 = 0.17, p 0.001). Conclusion: Both Goldmann applanation tonometry and non-contact tonometry are influenced by central corneal thickness. However, non-contact tonometry was significantly more sensitive to central corneal thickness variations compared to Goldmann applanation tonometry.

Authors

Institutions

Publication Details

Journal
Advanced medical journal
Published
2025-06-02
DOI
https://doi.org/10.56056/amj.2025.360
Primary Topic
Corneal surgery and disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of Central Corneal Thickness on The Intraocular Pressure as Measured by Different Tonometers: Non-Contact Tonometer and Goldmann Applanation Tonometer

Tara Hassan, Yaseen Ahmed Ali
Advanced medical journal
Corneal surgery and disorders
article

The Influence of Central Corneal Thickness on The Intraocular Pressure as Measured by Different Tonometers: Non-Contact Tonometer and Goldmann Applanation Tonometer

Tara Hassan, Yaseen Ahmed Ali
article en

Abstract

Background and objectives: Intraocular pressure plays a crucial role in maintaining vision and preventing eye disease. Beyond its importance in diagnosing and managing glaucoma, intraocular pressure measurements significantly impact the evaluation of postoperative outcomes, complications and optimize patient recovery. This study quantifies the influence of central corneal thickness on intraocular pressure using both Goldmann applanation tonometer and non-contact tonometer. Methods: In a prospective clinical trial, the subjects were recruited from glaucoma unit at Shahid Dr. Aso Eye Hospital in Sulaimania city/Iraq between January and June 2023. Intraocular pressure measurements were conducted in a randomized sequence for both eyes using both Goldmann applanation tonometry and non-contact tonometry exploring the correlation between measured inter-tonometer discrepancies employing linear regression analysis with central corneal thickness. Results: The study included 200 eyes of 100 consecutive patients diagnosed with either ocular hypertension or glaucoma. Mean age was 56.8 years, male (55%) and female (45%). Mean central corneal thickness was 533 ± 42 ?m and mean intra ocular pressure were 14.9 ± 4.3 mm Hg, 19.3 ± 5.4 mm Hg for Goldmann applanation tonometry and non-contact tonometry, respectively. There is a statistically significant relationship between central corneal thickness and intraocular pressure by Goldmann applanation tonometry (r2 = 0.1, p 0.001) and non-contact tonometry (r2 = 0.17, p 0.001). Conclusion: Both Goldmann applanation tonometry and non-contact tonometry are influenced by central corneal thickness. However, non-contact tonometry was significantly more sensitive to central corneal thickness variations compared to Goldmann applanation tonometry.

Advanced medical journalVol. 10(2)
He Eye Hospital (CN), University of Sulaimani (IQ)
Openalex Percentile: Top 81%
Corneal surgery and disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Influence of Central Corneal Thickness on The Intraocular Pressure as Measured by Different Tonometers: Non-Contact Tonometer and Goldmann Applanation Tonometer — Tara Hassan, Yaseen Ahmed Ali · Advanced medical journal (2025) | TGRS Research Map | TGRS