Different 212Pb Generators and Its Radiation Safety Concerning 220Rn (Thoron) Emanation

(1) Background: As the demand for <sup>212</sup>Pb for clinical theranostics rises, empirical studies that examine the radiation safety implications of different <sup>224</sup>Ra sources are needed to facilitate discussions with local authorities for the translation of <sup>203/212</sup>Pb theranostics routine clinical practice. (2) Methods: Environmental <sup>220</sup>Rn (Thoron) emanation was detected by a RAD7 detector in the vicinity of respective <sup>212</sup>Pb sources and additional alpha-dosimeters to detect <sup>220</sup>Rn during generator elution, radiosynthesis, and quality control. Personnel gamma exposure was measured using whole-body and ring dosimeters. Generators included those based on wet-chemical-process- and emanation-based technology. (3) Results: During generator handling, varying levels of <sup>220</sup>Rn were observed in the vicinity of generators. An additional monthly whole-body dose must be considered when handling different sources of <sup>212</sup>Pb generators, and this depends upon local shielding and the handling approaches toward use of the technology. (4) Conclusions: <sup>224</sup>Ra in any form (including radionuclide generators) should always be handled within a fume hood to keep potential contamination and exposure to personnel as low as reasonably achievable. Following standard practices of radiation safety, generators of <sup>212</sup>Pb can be used safely for theranostic applications.

Authors

Institutions

Publication Details

Journal
Toxics
Published
2025-05-30
DOI
https://doi.org/10.3390/toxics13060462
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Different 212Pb Generators and Its Radiation Safety Concerning 220Rn (Thoron) Emanation

David Kästner, Ralph A. Bundschuh, Michael K. Schultz, Edwin A. Sagastume et al.
Toxics
Radiation Dose and Imaging
article

Different 212Pb Generators and Its Radiation Safety Concerning 220Rn (Thoron) Emanation

David Kästner, Ralph A. Bundschuh, Michael K. Schultz, Edwin A. Sagastume, Thierry Storà, Marc Pretze, Charlotte Duchemin, Robert Freudenberg, Holger Hartmann, Jörg Kotzerke, Muhammad Inzamam
article en

Abstract

(1) Background: As the demand for <sup>212</sup>Pb for clinical theranostics rises, empirical studies that examine the radiation safety implications of different <sup>224</sup>Ra sources are needed to facilitate discussions with local authorities for the translation of <sup>203/212</sup>Pb theranostics routine clinical practice. (2) Methods: Environmental <sup>220</sup>Rn (Thoron) emanation was detected by a RAD7 detector in the vicinity of respective <sup>212</sup>Pb sources and additional alpha-dosimeters to detect <sup>220</sup>Rn during generator elution, radiosynthesis, and quality control. Personnel gamma exposure was measured using whole-body and ring dosimeters. Generators included those based on wet-chemical-process- and emanation-based technology. (3) Results: During generator handling, varying levels of <sup>220</sup>Rn were observed in the vicinity of generators. An additional monthly whole-body dose must be considered when handling different sources of <sup>212</sup>Pb generators, and this depends upon local shielding and the handling approaches toward use of the technology. (4) Conclusions: <sup>224</sup>Ra in any form (including radionuclide generators) should always be handled within a fume hood to keep potential contamination and exposure to personnel as low as reasonably achievable. Following standard practices of radiation safety, generators of <sup>212</sup>Pb can be used safely for theranostic applications.

ToxicsVol. 13(6)
University of Iowa (US), University Hospital Carl Gustav Carus (DE), European Organization for Nuclear Research (CH)
European Commission
Openalex Percentile: Top 81%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.