Level of Agreement of Intraocular Lens Power Measurements Between a Swept-Source OCT Biometer and a Partial Coherence Interferometer

<b>Background/Objectives</b>: Swept-Source Optical Coherence Tomography (SS-OCT) is a novel optical biometry technology with limited published data on its reliability compared to the gold standard, partial coherence interferometry (PCI). This study aims to assess the agreement between an SS-OCT biometer (Argos) and a PCI device (IOLMaster 500) in terms of biometry values, intraocular lens (IOL) power calculation and mean prediction error (ME). <b>Methods</b>: In this prospective comparative study, axial length (AL), anterior chamber depth (ACD), flat (K1), steep (K2) and mean (Km) keratometry values, astigmatism power, J0, and J45 vector components, white-to-white distance (WTW), and IOL power calculations for nine IOL models using four formulas were compared in cataract patients. Refractive outcomes were assessed in eyes implanted with SN60WF and Panoptix IOLs, with ME calculated for each module and formula for both IOLs postoperatively. <b>Results</b>: This study included 133 eyes (mean age: 66.0 ± 10.95 years). Argos measured significantly higher ACD and steeper keratometry values than IOLMaster, albeit without significant differences in AL, astigmatism power, WTW, J0, and J45. Mean IOL power differences were within the clinically acceptable threshold (0.50 D), except for SN6ATx with Hoffer Q and Haigis, and Clareon with Haigis. For Panoptix and SN60WF, IOLMaster demonstrated a more hyperopic ME than Argos with SRK/T, Holladay 1, and Hoffer Q; however, this was without clinically significant differences. <b>Conclusions</b>: Argos and IOLMaster 500 presented differences in ACD, keratometry values, and IOL power calculation. However, both devices showed non-clinically significant differences in IOL power calculation and ME in the majority of formulas.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-06-02
DOI
https://doi.org/10.3390/jcm14113903
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Level of Agreement of Intraocular Lens Power Measurements Between a Swept-Source OCT Biometer and a Partial Coherence Interferometer

Minas Bakirtzis, Ioannis Tsinopoulos, Nikolaos Ziakas, Eirini-Kanella Panagiotopoulou et al.
Journal of Clinical Medicine
Intraocular Surgery and Lenses
article

Level of Agreement of Intraocular Lens Power Measurements Between a Swept-Source OCT Biometer and a Partial Coherence Interferometer

Minas Bakirtzis, Ioannis Tsinopoulos, Nikolaos Ziakas, Eirini-Kanella Panagiotopoulou, Georgios Labiris, Thomas Polychroniadis
article en

Abstract

<b>Background/Objectives</b>: Swept-Source Optical Coherence Tomography (SS-OCT) is a novel optical biometry technology with limited published data on its reliability compared to the gold standard, partial coherence interferometry (PCI). This study aims to assess the agreement between an SS-OCT biometer (Argos) and a PCI device (IOLMaster 500) in terms of biometry values, intraocular lens (IOL) power calculation and mean prediction error (ME). <b>Methods</b>: In this prospective comparative study, axial length (AL), anterior chamber depth (ACD), flat (K1), steep (K2) and mean (Km) keratometry values, astigmatism power, J0, and J45 vector components, white-to-white distance (WTW), and IOL power calculations for nine IOL models using four formulas were compared in cataract patients. Refractive outcomes were assessed in eyes implanted with SN60WF and Panoptix IOLs, with ME calculated for each module and formula for both IOLs postoperatively. <b>Results</b>: This study included 133 eyes (mean age: 66.0 ± 10.95 years). Argos measured significantly higher ACD and steeper keratometry values than IOLMaster, albeit without significant differences in AL, astigmatism power, WTW, J0, and J45. Mean IOL power differences were within the clinically acceptable threshold (0.50 D), except for SN6ATx with Hoffer Q and Haigis, and Clareon with Haigis. For Panoptix and SN60WF, IOLMaster demonstrated a more hyperopic ME than Argos with SRK/T, Holladay 1, and Hoffer Q; however, this was without clinically significant differences. <b>Conclusions</b>: Argos and IOLMaster 500 presented differences in ACD, keratometry values, and IOL power calculation. However, both devices showed non-clinically significant differences in IOL power calculation and ME in the majority of formulas.

Journal of Clinical MedicineVol. 14(11)
Aristotle University of Thessaloniki (GR), Papageorgiou General Hospital (GR), University Hospital of Alexandroupolis (GR)
Openalex Percentile: Top 80%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.