Measurement of Effective Half-life of Iodine-131 to Optimize Safety Release Instructions after Treatment for Patients with Differentiated Thyroid Cancer

Iodine-131 ( 131 I) is a common therapy for treatment of differentiated thyroid carcinoma (DTC); however, its radioactivity poses a radiation safety risk to public health. There is inter-facility variation in release instructions to minimize incident exposure to other individuals. Isolation measures are not without harm. Most studies on this topic rely upon cumulative dosimetry to measure exposure, but this does not provide the researcher with critical dose protraction information. Refining estimation of elimination kinetics with more frequent exposure readings would help optimize radiation safety recommendations. Measuring radiation exposure from patients with DTC post-thyroidectomy receiving 131 I would better quantify its elimination kinetics to improve radiation safety recommendations. Patients with DTC post-thyroidectomy undergoing radioiodine remnant ablation with 131 I were instructed to measure exposure at a distance of 1 m, three times a day for 14 d, using an ion chamber at home. These data were used to form an exponential decay model and estimate the time after which cumulative exposure is below a reasonably low threshold. The average effective half-life was 15.8 h when calculated using real-time exposure readings from 32 patients. Among patients administered less than 4.22 GBq, cumulative effective dose is ≤1 mSv after 24 h of isolation. Between 4.22 and 6.03 GBq, cumulative effective dose is ≤1mSv after 48 h of isolation. Cumulative gamma radiation exposure at 1 m remains low enough to consider re-evaluating isolation protocols that encourage long-term distancing past the first 24 h in post-thyroidectomy patients treated with 131I for remnant ablation.

Authors

Institutions

Publication Details

Journal
Health Physics
Published
2025-05-30
DOI
https://doi.org/10.1097/hp.0000000000001997
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Measurement of Effective Half-life of Iodine-131 to Optimize Safety Release Instructions after Treatment for Patients with Differentiated Thyroid Cancer

Aaron T. Smith, T Greist
1 links
Health Physics
Radiation Dose and Imaging
article

Measurement of Effective Half-life of Iodine-131 to Optimize Safety Release Instructions after Treatment for Patients with Differentiated Thyroid Cancer

Aaron T. Smith, T Greist
article en

Abstract

Iodine-131 ( 131 I) is a common therapy for treatment of differentiated thyroid carcinoma (DTC); however, its radioactivity poses a radiation safety risk to public health. There is inter-facility variation in release instructions to minimize incident exposure to other individuals. Isolation measures are not without harm. Most studies on this topic rely upon cumulative dosimetry to measure exposure, but this does not provide the researcher with critical dose protraction information. Refining estimation of elimination kinetics with more frequent exposure readings would help optimize radiation safety recommendations. Measuring radiation exposure from patients with DTC post-thyroidectomy receiving 131 I would better quantify its elimination kinetics to improve radiation safety recommendations. Patients with DTC post-thyroidectomy undergoing radioiodine remnant ablation with 131 I were instructed to measure exposure at a distance of 1 m, three times a day for 14 d, using an ion chamber at home. These data were used to form an exponential decay model and estimate the time after which cumulative exposure is below a reasonably low threshold. The average effective half-life was 15.8 h when calculated using real-time exposure readings from 32 patients. Among patients administered less than 4.22 GBq, cumulative effective dose is ≤1 mSv after 24 h of isolation. Between 4.22 and 6.03 GBq, cumulative effective dose is ≤1mSv after 48 h of isolation. Cumulative gamma radiation exposure at 1 m remains low enough to consider re-evaluating isolation protocols that encourage long-term distancing past the first 24 h in post-thyroidectomy patients treated with 131I for remnant ablation.

Health PhysicsVol. 130(1)
St. Vincent Hospital (US)
Good health and well-being
Openalex Percentile: Top 81%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.