<b>Background and Objectives:</b> Labor progression evaluation through repeated vaginal examinations remains the primary method of monitoring in delivery rooms globally. Transperineal intrapartum ultrasound has been shown to be reliable for assessing cervical dilatation, with substantial concordance with digital vaginal examinations. However, none of the analyzed studies investigated the influence of membrane integrity on ultrasound measurements. This study assessed the impact of membrane status on cervical dilatation evaluation via transperineal ultrasound compared to clinical examination, and the extent of agreement based on dilatation level and membrane status. <b>Methods</b>: A nine-month longitudinal observational study was conducted in the Obstetrics and Gynecology Clinic of "Sfântul Pantelimon" Clinical Emergency Hospital (Bucharest, Romania). Patients underwent two clinical examinations and two transperineal ultrasound measurements, one at a dilatation less than 8 cm and the other at a dilatation closer to full dilatation (above 8 cm). Agreement between clinical and ultrasound measurements was analyzed based on membrane integrity and dilatation level. <b>Results</b>: In total, 239 patients were included, and 478 cervical dilatation measurements were obtained. Only the 7-8 cm subgroup exhibited statistically significant differences in accuracy between patients with intact and ruptured membranes. The Pearson correlation results for membrane status were 0.87 (p-value < 0.001) for intact membranes and 0.91 (p-value < 0.001) for ruptured membranes. Both groups show a strong positive correlation, suggesting that ultrasound and clinical measurements tend to increase simultaneously, regardless of membrane status. <b>Conclusions</b>: Transperineal ultrasound is useful for labor monitoring, but its accuracy decreases significantly in advanced labor, especially beyond 8 cm dilatation and in cases with ruptured membranes.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2025-06-02
DOI
https://doi.org/10.3390/healthcare13111322
Primary Topic
Pelvic floor disorders treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Membrane Status and Reliability of Intrapartum Transperineal Ultrasound in Cervical Dilatation Assessment

Crîngu Antoniu Ionescu, Dan Năvolan, Adrian Neacşu, George-Alexandru Roșu et al.
Healthcare
Pelvic floor disorders treatments
article

Membrane Status and Reliability of Intrapartum Transperineal Ultrasound in Cervical Dilatation Assessment

Crîngu Antoniu Ionescu, Dan Năvolan, Adrian Neacşu, George-Alexandru Roșu, Ștefan-Florentin Semeș
article en

Abstract

<b>Background and Objectives:</b> Labor progression evaluation through repeated vaginal examinations remains the primary method of monitoring in delivery rooms globally. Transperineal intrapartum ultrasound has been shown to be reliable for assessing cervical dilatation, with substantial concordance with digital vaginal examinations. However, none of the analyzed studies investigated the influence of membrane integrity on ultrasound measurements. This study assessed the impact of membrane status on cervical dilatation evaluation via transperineal ultrasound compared to clinical examination, and the extent of agreement based on dilatation level and membrane status. <b>Methods</b>: A nine-month longitudinal observational study was conducted in the Obstetrics and Gynecology Clinic of "Sfântul Pantelimon" Clinical Emergency Hospital (Bucharest, Romania). Patients underwent two clinical examinations and two transperineal ultrasound measurements, one at a dilatation less than 8 cm and the other at a dilatation closer to full dilatation (above 8 cm). Agreement between clinical and ultrasound measurements was analyzed based on membrane integrity and dilatation level. <b>Results</b>: In total, 239 patients were included, and 478 cervical dilatation measurements were obtained. Only the 7-8 cm subgroup exhibited statistically significant differences in accuracy between patients with intact and ruptured membranes. The Pearson correlation results for membrane status were 0.87 (p-value < 0.001) for intact membranes and 0.91 (p-value < 0.001) for ruptured membranes. Both groups show a strong positive correlation, suggesting that ultrasound and clinical measurements tend to increase simultaneously, regardless of membrane status. <b>Conclusions</b>: Transperineal ultrasound is useful for labor monitoring, but its accuracy decreases significantly in advanced labor, especially beyond 8 cm dilatation and in cases with ruptured membranes.

HealthcareVol. 13(11)
Carol Davila University of Medicine and Pharmacy (RO), Clinical Emergency Hospital Bucharest (RO), Victor Babeș University of Medicine and Pharmacy Timișoara (RO)
Openalex Percentile: Top 81%
Pelvic floor disorders treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.