Evaluation of passive samplers for cyanotoxin detection by immunoassay and chromatographic-mass spectrometry

Harmful algal blooms, particularly cyanobacterial harmful algal blooms, threaten aquatic ecosystems, drinking water supplies, and recreational resources.In 2019, the U.S. Geological Survey, in collaboration with the New York State Department of Environmental Conservation, deployed solid phase adsorption toxin tracking (SPATT) samplers in Seneca Lake, Owasco Lake, and Skaneateles Lake to monitor the cyanotoxins microcystins, cylindrospermopsins, anatoxins, and saxitoxins.SPATT samplers can passively adsorb dissolved cyanotoxins over time, providing time-integrated data capable of detecting low concentrations of cyanotoxins that traditional discrete sampling may miss.SPATT samples were analyzed using enzyme-linked immunosorbent assay (ELISA), liquid chromatography with mass spectrometry (LC-MS), and with tandem mass spectrometry (LC-MS/MS).The effects of ELISA-required preservative on measurements by mass spectrometry methods were also evaluated.SPATT samplers consistently detected microcystins and anatoxins more frequently than concurrent discrete sampling.ELISA results often showed higher cyanotoxin concentrations than LC-MS/MS, likely due to interference from dissolved organic matter and the ability of ELISA to detect a broader range of congeners.The addition of preservative influenced results for some analytes, particularly microcystins, which showed higher concentrations in preserved samples.Limitations in ELISA methods for cylindrospermopsins and saxitoxins were identified, potentially related to cross-reactivity, low sensitivity, or other matrix interferences.This study demonstrates the utility of SPATT samplers in capturing cyanotoxin variability, especially in environments with low cyanotoxin levels or ephemeral blooms.Further research could help improve the reliability of ELISA and other analytical methods in freshwater ecosystems.

Authors

Publication Details

Journal
Scientific investigations report
Published
2025-01-01
DOI
https://doi.org/10.3133/sir20255046
Primary Topic
Marine Toxins and Detection Methods
Type
article

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of passive samplers for cyanotoxin detection by immunoassay and chromatographic-mass spectrometry

Bofan Wei, Brett D. Johnston, Joshua J. Rosen, Gregory L. Boyer et al.
Scientific investigations report
Marine Toxins and Detection Methods
article

Evaluation of passive samplers for cyanotoxin detection by immunoassay and chromatographic-mass spectrometry

Bofan Wei, Brett D. Johnston, Joshua J. Rosen, Gregory L. Boyer, Michael D. Stouder, Kurt D. Carpenter, Rebecca M. Gorney
article en

Abstract

Harmful algal blooms, particularly cyanobacterial harmful algal blooms, threaten aquatic ecosystems, drinking water supplies, and recreational resources.In 2019, the U.S. Geological Survey, in collaboration with the New York State Department of Environmental Conservation, deployed solid phase adsorption toxin tracking (SPATT) samplers in Seneca Lake, Owasco Lake, and Skaneateles Lake to monitor the cyanotoxins microcystins, cylindrospermopsins, anatoxins, and saxitoxins.SPATT samplers can passively adsorb dissolved cyanotoxins over time, providing time-integrated data capable of detecting low concentrations of cyanotoxins that traditional discrete sampling may miss.SPATT samples were analyzed using enzyme-linked immunosorbent assay (ELISA), liquid chromatography with mass spectrometry (LC-MS), and with tandem mass spectrometry (LC-MS/MS).The effects of ELISA-required preservative on measurements by mass spectrometry methods were also evaluated.SPATT samplers consistently detected microcystins and anatoxins more frequently than concurrent discrete sampling.ELISA results often showed higher cyanotoxin concentrations than LC-MS/MS, likely due to interference from dissolved organic matter and the ability of ELISA to detect a broader range of congeners.The addition of preservative influenced results for some analytes, particularly microcystins, which showed higher concentrations in preserved samples.Limitations in ELISA methods for cylindrospermopsins and saxitoxins were identified, potentially related to cross-reactivity, low sensitivity, or other matrix interferences.This study demonstrates the utility of SPATT samplers in capturing cyanotoxin variability, especially in environments with low cyanotoxin levels or ephemeral blooms.Further research could help improve the reliability of ELISA and other analytical methods in freshwater ecosystems.

Scientific investigations report
New York State Department of Environmental Conservation, U.S. Geological Survey
Marine Toxins and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.