Pulsatile Physiological Control of Blood Pump-Cardiovascular System Based on Feedforward Compensation

Rotary Blood Pump (RBP) is a commonly used ventricular assist device. However, the constant speed operation of the blood pump leads to a reduction of blood flow pulsatility, which triggers a series of adverse reactions. In this paper, a pulsatile physiological control with feed-forward compensation (FFC) is designed to regulate the rotational speed in real time to accurately output pulsatile blood flow to address this problem. The coupled model of the Rotary Blood Pump and cardiovascular system (CVS) is established in the SIMULINK software as the research object. The designed pulsatile physiological control algorithm contains the feed-forward compensation-based pulsatile control and anti-reflux algorithm, switching the applicable algorithm based on the pump flow. When the flow rate is higher than the threshold, feed-forward compensation is introduced and combined with PI feedback control to improve the performance of pulsation tracking; when the flow rate is lower than the threshold, it is switched to the anti-reflux algorithm to gradually increase the pump speed. Simulation shows that the designed feed-forward compensation link reduces the tracking error of the pulsatile physiological control by 80%. In the case of a 50% sudden change of physiological parameters, it can track quickly and stably and avoid reflux. The pulsatile performance and ventricular unloading performance are better compared with no feed-forward compensation pulsation control as well as constant-speed control. An increase of 30 mmHg in aortic beat-to-beat differential pressure was achieved in the extracorporeal circulation experiments, which is important for the realization of pulsatile flow control of the Rotary Blood Pump.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-05-31
DOI
https://doi.org/10.3390/mi16060664
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulsatile Physiological Control of Blood Pump-Cardiovascular System Based on Feedforward Compensation

Jing Teng, Ling Hui Zhou, Yanjun Bao, Weimin Ru
Micromachines
Mechanical Circulatory Support Devices
article

Pulsatile Physiological Control of Blood Pump-Cardiovascular System Based on Feedforward Compensation

Jing Teng, Ling Hui Zhou, Yanjun Bao, Weimin Ru
article en

Abstract

Rotary Blood Pump (RBP) is a commonly used ventricular assist device. However, the constant speed operation of the blood pump leads to a reduction of blood flow pulsatility, which triggers a series of adverse reactions. In this paper, a pulsatile physiological control with feed-forward compensation (FFC) is designed to regulate the rotational speed in real time to accurately output pulsatile blood flow to address this problem. The coupled model of the Rotary Blood Pump and cardiovascular system (CVS) is established in the SIMULINK software as the research object. The designed pulsatile physiological control algorithm contains the feed-forward compensation-based pulsatile control and anti-reflux algorithm, switching the applicable algorithm based on the pump flow. When the flow rate is higher than the threshold, feed-forward compensation is introduced and combined with PI feedback control to improve the performance of pulsation tracking; when the flow rate is lower than the threshold, it is switched to the anti-reflux algorithm to gradually increase the pump speed. Simulation shows that the designed feed-forward compensation link reduces the tracking error of the pulsatile physiological control by 80%. In the case of a 50% sudden change of physiological parameters, it can track quickly and stably and avoid reflux. The pulsatile performance and ventricular unloading performance are better compared with no feed-forward compensation pulsation control as well as constant-speed control. An increase of 30 mmHg in aortic beat-to-beat differential pressure was achieved in the extracorporeal circulation experiments, which is important for the realization of pulsatile flow control of the Rotary Blood Pump.

MicromachinesVol. 16(6)
Jiangsu University (CN)
National Natural Science Foundation of China
Good health and well-being
Openalex Percentile: Top 89%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.