Early Detection of Hydrogen Leakage Using Fiber Optic Hydrogen Sensor Based on WO3-PdPt-Pt Nanocomposite Films

Quickly detecting hydrogen leakage is crucial to provide early warning for taking emergency measures to avoid personnel casualties and explosion accidents in hydrogen energy fields. Here, a compact optical fiber hydrogen sensing system with high sensitivity and quick response rate is proposed in this work. A laser diode (LD) and two photodetectors (PD) are employed as light source and optical signal transformation devices, respectively. This sensing system employs single-mode optical fiber deposited with WO<sub>3</sub>-PdPt-Pt nanocomposite film system as sensing element. Under irrigating power of 6 mW, the sensing probe exhibits an ultra-fast response to hydrogen concentrations of 4000 ppm and 10,000 ppm, with response times of 0.44 s and 0.34 s, respectively. In addition, detection limit of 3 ppm can be achieved by using this sensing system. The sensor also shows good repeatability during hydrogen exposure of 3~10,000 ppm, demonstrating its great potential application for hydrogen leakage in hydrogen energy facilities.

Authors

Institutions

Publication Details

Journal
Nanomaterials
Published
2025-05-30
DOI
https://doi.org/10.3390/nano15110836
Citations
6
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
4.38

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Early Detection of Hydrogen Leakage Using Fiber Optic Hydrogen Sensor Based on WO3-PdPt-Pt Nanocomposite Films

Zhouyang Wu, Cheng Cheng, Renjie Yang, Xuewen Wang et al.
6 citations
Nanomaterials
Gas Sensing Nanomaterials and Sensors
4.38
article

Early Detection of Hydrogen Leakage Using Fiber Optic Hydrogen Sensor Based on WO3-PdPt-Pt Nanocomposite Films

Zhouyang Wu, Cheng Cheng, Renjie Yang, Xuewen Wang, Wenbin Hu, Jixiang Dai, Zhangning Chen, Zirong Tang
article en
6 citations

Abstract

Quickly detecting hydrogen leakage is crucial to provide early warning for taking emergency measures to avoid personnel casualties and explosion accidents in hydrogen energy fields. Here, a compact optical fiber hydrogen sensing system with high sensitivity and quick response rate is proposed in this work. A laser diode (LD) and two photodetectors (PD) are employed as light source and optical signal transformation devices, respectively. This sensing system employs single-mode optical fiber deposited with WO<sub>3</sub>-PdPt-Pt nanocomposite film system as sensing element. Under irrigating power of 6 mW, the sensing probe exhibits an ultra-fast response to hydrogen concentrations of 4000 ppm and 10,000 ppm, with response times of 0.44 s and 0.34 s, respectively. In addition, detection limit of 3 ppm can be achieved by using this sensing system. The sensor also shows good repeatability during hydrogen exposure of 3~10,000 ppm, demonstrating its great potential application for hydrogen leakage in hydrogen energy facilities.

NanomaterialsVol. 15(11)
Wuhan University of Technology (CN), Sanya University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 6%
Gas Sensing Nanomaterials and Sensors
4.38
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Early Detection of Hydrogen Leakage Using Fiber Optic Hydrogen Sensor Based on WO3-PdPt-Pt Nanocomposite Films — Zhouyang Wu, Cheng Cheng, et al. · Nanomaterials (2025) | TGRS Research Map | TGRS