Multisensor Fusion for Noninvasive Worker Health Monitoring in Industry 4.0

Workers’ health state monitoring in Industry 4.0 is crucial for the prevention of work-related musculoskeletal disorders caused by repetitive movements. Electromyographic signals (EMG) are commonly used for detecting muscle activity and assessing muscle load. Unfortunately, accurate processing and analysis of EMG remain challenging due to the nonlinear nature of this signal. To enhance the accuracy of muscle activity analysis, this study employs wearable sensors to concurrently monitor electrocardiographic (ECG), EMG, accelerometric, gyroscopic, and magnetometric signals using two synchronized Shimmer3 ECG/EMG units. These signals were recorded and analysed on 13 volunteers during 8 different scenarios of repetitive upper limb movements commonly encountered in Industry 4.0 environments. Heart activity was evaluated using ECG, achieving an average accuracy of 88.8% in R-peak detection, with average values of μ and ±1.96σ being 0.2 bpm and 12.6 bpm, respectively, in heart rate determination. Heart rate variability analysis was conducted, revealing varying degrees of stress or fatigue in most cases. Physical activity detection was performed using two separate approaches: 1) an EMG signal analysis method and 2) a newly introduced accelerometer-gyroscope-magnetometer (AGM) method. The AGM method developed in this study demonstrated superior performance compared to the EMG method, with an average accuracy of 96.4% compared to 45.5% for EMG. Muscle fatigue quantification was effectively performed by analyzing the frequency characteristics of EMG. The results of this study confirmed the potential of wearable sensors for monitoring the health status of workers in Industry 4.0 environments, with a focus on the application of the novel AGM method.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3576005
Citations
2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multisensor Fusion for Noninvasive Worker Health Monitoring in Industry 4.0

Michal Prauzek, Radek Martínek, Katerina Barnova, Lukáš Danys et al.
2 citations
IEEE Transactions on Instrumentation and Measurement
Non-Invasive Vital Sign Monitoring
1.35
article

Multisensor Fusion for Noninvasive Worker Health Monitoring in Industry 4.0

Michal Prauzek, Radek Martínek, Katerina Barnova, Lukáš Danys, Jaromír Konecny, René Jaroš, Jan Pelisek
article en
2 citations

Abstract

Workers’ health state monitoring in Industry 4.0 is crucial for the prevention of work-related musculoskeletal disorders caused by repetitive movements. Electromyographic signals (EMG) are commonly used for detecting muscle activity and assessing muscle load. Unfortunately, accurate processing and analysis of EMG remain challenging due to the nonlinear nature of this signal. To enhance the accuracy of muscle activity analysis, this study employs wearable sensors to concurrently monitor electrocardiographic (ECG), EMG, accelerometric, gyroscopic, and magnetometric signals using two synchronized Shimmer3 ECG/EMG units. These signals were recorded and analysed on 13 volunteers during 8 different scenarios of repetitive upper limb movements commonly encountered in Industry 4.0 environments. Heart activity was evaluated using ECG, achieving an average accuracy of 88.8% in R-peak detection, with average values of μ and ±1.96σ being 0.2 bpm and 12.6 bpm, respectively, in heart rate determination. Heart rate variability analysis was conducted, revealing varying degrees of stress or fatigue in most cases. Physical activity detection was performed using two separate approaches: 1) an EMG signal analysis method and 2) a newly introduced accelerometer-gyroscope-magnetometer (AGM) method. The AGM method developed in this study demonstrated superior performance compared to the EMG method, with an average accuracy of 96.4% compared to 45.5% for EMG. Muscle fatigue quantification was effectively performed by analyzing the frequency characteristics of EMG. The results of this study confirmed the potential of wearable sensors for monitoring the health status of workers in Industry 4.0 environments, with a focus on the application of the novel AGM method.

IEEE Transactions on Instrumentation and MeasurementVol. 74
VSB - Technical University of Ostrava (CZ)
Decent work and economic growth
Openalex Percentile: Top 20%
Non-Invasive Vital Sign Monitoring
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.