A Novel Dual-Band MIMO-Enabled Biotelemetric Endovascular Stent IoMT System

Recent advancements in the Internet of Medical Things (IoMT) have necessitated the need of smart biomedical devices. This paper presents a novel endovascular aneurysm repair (EVAR) stent system integrated with a flexible antenna for seamless data telemetry and post-EVAR surveillance with high data rates. Employing multiple-input multiple-output (MIMO) technology, the antenna consists of four dipoles with each element designed and optimized to offer dual band resonance at the two industrial, scientific, and medical (ISM) bands, i.e., 915 and 2450 MHz. To validate the performance of MIMO EVAR stent antenna, simulations were conducted both in the homogeneous tissue and realistic human model. Experimental validations were performed in a saline-filled American Society for Testing and Materials phantom and minced pork. The MIMO stent antenna exhibits several key features including better impedance matching characteristics, high impedance bandwidth of 380 MHz (720–1100 MHz) and 440 MHz (2240–2680 MHz), and excellent far-field radiation performance with high gain values of -11.5 and -9.8 at 915 and 2450 MHz, respectively. Remarkably, the proposed IoMT-enabled smart medical device can support a high data rate of 12 Mbps with the communication range up to 11 m at 915 MHz and 13 m at 2450 MHz, achieved in a real-time data telemetry experiment. Moreover, the MIMO channel parameters were examined to ensure seamless communication and independence between MIMO elements. Specific absorption rate analysis confirmed the safety of the proposed MIMO antenna system. To the best of the authors’ knowledge, this is the first study to develop MIMO-based EVAR stent system with significant features, thereby making it a viable solution for advanced IoMT-enabled healthcare systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3576004
Citations
5
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
3.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel Dual-Band MIMO-Enabled Biotelemetric Endovascular Stent IoMT System

Izaz Ali Shah, Hyoungsuk Yoo, Zain U Abdin, Syed Ahson Ali Shah et al.
5 citations
IEEE Transactions on Instrumentation and Measurement
Wireless Body Area Networks
3.37
article

A Novel Dual-Band MIMO-Enabled Biotelemetric Endovascular Stent IoMT System

Izaz Ali Shah, Hyoungsuk Yoo, Zain U Abdin, Syed Ahson Ali Shah, Usman Rizqi Iman, Sajjad Hussain Mian
article en
5 citations

Abstract

Recent advancements in the Internet of Medical Things (IoMT) have necessitated the need of smart biomedical devices. This paper presents a novel endovascular aneurysm repair (EVAR) stent system integrated with a flexible antenna for seamless data telemetry and post-EVAR surveillance with high data rates. Employing multiple-input multiple-output (MIMO) technology, the antenna consists of four dipoles with each element designed and optimized to offer dual band resonance at the two industrial, scientific, and medical (ISM) bands, i.e., 915 and 2450 MHz. To validate the performance of MIMO EVAR stent antenna, simulations were conducted both in the homogeneous tissue and realistic human model. Experimental validations were performed in a saline-filled American Society for Testing and Materials phantom and minced pork. The MIMO stent antenna exhibits several key features including better impedance matching characteristics, high impedance bandwidth of 380 MHz (720–1100 MHz) and 440 MHz (2240–2680 MHz), and excellent far-field radiation performance with high gain values of -11.5 and -9.8 at 915 and 2450 MHz, respectively. Remarkably, the proposed IoMT-enabled smart medical device can support a high data rate of 12 Mbps with the communication range up to 11 m at 915 MHz and 13 m at 2450 MHz, achieved in a real-time data telemetry experiment. Moreover, the MIMO channel parameters were examined to ensure seamless communication and independence between MIMO elements. Specific absorption rate analysis confirmed the safety of the proposed MIMO antenna system. To the best of the authors’ knowledge, this is the first study to develop MIMO-based EVAR stent system with significant features, thereby making it a viable solution for advanced IoMT-enabled healthcare systems.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Hanyang University (KR)
National Research Foundation of Korea
Affordable and clean energy
Openalex Percentile: Top 8%
Wireless Body Area Networks
3.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.