Time Coordinated Control Strategy to Improve Voltage Balance and Regulation of Low Voltage PV Rich Networks

Typically, a PV-rich low voltage active distribution system (LV-ADS) suffers from voltage unbalance issue during high irradiance period. Lack of proper planning in deploying PVbased single-phase converters (SPCs) in the LV-ADS causes a high phase voltage unbalance factor (PVUF), leading to the tripping of three phase converters (TPCs). The IEEE 1547-2020 code does not mandate SPCs to undertake any preventive measure to reduce the PVUF of LV-ADS. The code recommends TPCs to participate in voltage regulation of the network. However, due to tripping of the TPCs, the voltage regulation degrades. Two new algorithms are proposed in this paper; coordinated leader-follower feedback-based algorithm and cluster selection algorithm which are combined together to resolve the abovementioned issues. The proposed approach is demonstrated in the European LV-ADS test bench to validate its superiority over IEEE 1547-2020 and SOCP based ACOPF methods.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Power Delivery
Published
2025-06-02
DOI
https://doi.org/10.1109/tpwrd.2025.3575795
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time Coordinated Control Strategy to Improve Voltage Balance and Regulation of Low Voltage PV Rich Networks

Sukumar Mishra, Priyatosh Mahish, Manas Ranjan Mishra
IEEE Transactions on Power Delivery
Optimal Power Flow Distribution
article

Time Coordinated Control Strategy to Improve Voltage Balance and Regulation of Low Voltage PV Rich Networks

Sukumar Mishra, Priyatosh Mahish, Manas Ranjan Mishra
article en

Abstract

Typically, a PV-rich low voltage active distribution system (LV-ADS) suffers from voltage unbalance issue during high irradiance period. Lack of proper planning in deploying PVbased single-phase converters (SPCs) in the LV-ADS causes a high phase voltage unbalance factor (PVUF), leading to the tripping of three phase converters (TPCs). The IEEE 1547-2020 code does not mandate SPCs to undertake any preventive measure to reduce the PVUF of LV-ADS. The code recommends TPCs to participate in voltage regulation of the network. However, due to tripping of the TPCs, the voltage regulation degrades. Two new algorithms are proposed in this paper; coordinated leader-follower feedback-based algorithm and cluster selection algorithm which are combined together to resolve the abovementioned issues. The proposed approach is demonstrated in the European LV-ADS test bench to validate its superiority over IEEE 1547-2020 and SOCP based ACOPF methods.

IEEE Transactions on Power DeliveryVol. 40(4)
Indian Institute of Technology Delhi (IN), Indian Institute of Technology Mandi (IN)
Affordable and clean energy
Openalex Percentile: Top 90%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.