Intra-rater within- and between-session reliability of TMS-induced MEPs: peak-to-peak amplitude versus area under the curve

Corticospinal excitability (CSE) is the responsiveness of the corticospinal and brain-to-muscle pathway, assessed using motor-evoked potentials (MEPs) via transcranial magnetic stimulation (TMS). It provides crucial insight into motor control, neuroplasticity, and neurological conditions. The use of TMS-induced MEPs in clinical and research contexts is contingent upon their intra- and intersession reliability. This study specifically aimed to assess the reliability of two distinct methods for quantifying MEP size: peak-to-peak amplitude (PPA) and the area under the curve (AUC). Establishing the agreement between these quantification methods is critical for ensuring consistent measurements by the same assessor, especially in pre- and post-test designs conducted within and between sessions. Twelve healthy participants volunteered for this study. Thirty MEPs were recorded from each participant using a single-pulse TMS set at 120% of the resting motor threshold (RMT) over two sessions. The first session consisted of two tests (T1 and T2) with a 20-minute rest interval between sets. The second session included one set of tests (T3). Test-retest reliability of MEP amplitude and AUC were assessed using one-way ANOVA and Intraclass Correlation Coefficient (ICC). A one-way ANOVA revealed no significant effect of time on MEP amplitude or AUC value, indicating agreement between sessions. The ICC demonstrated significant intra- and inter-session reliability for PPA. However, correlations between T1-T3 were weak for AUC values. In conclusion, this study suggests that PPA a more reliable measurement than AUC for assessing changes in CSE. Future investigations should explore the reliability of the AUC method in clinical settings or research protocols.

Authors

Institutions

Publication Details

Journal
Neuroscience Letters
Published
2025-06-02
DOI
https://doi.org/10.1016/j.neulet.2025.138283
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intra-rater within- and between-session reliability of TMS-induced MEPs: peak-to-peak amplitude versus area under the curve

Shapour Jaberzadeh, Mona Malekahmad, Maryam Zoghi, Ashlyn K. Frazer
Neuroscience Letters
Transcranial Magnetic Stimulation Studies
article

Intra-rater within- and between-session reliability of TMS-induced MEPs: peak-to-peak amplitude versus area under the curve

Shapour Jaberzadeh, Mona Malekahmad, Maryam Zoghi, Ashlyn K. Frazer
article en

Abstract

Corticospinal excitability (CSE) is the responsiveness of the corticospinal and brain-to-muscle pathway, assessed using motor-evoked potentials (MEPs) via transcranial magnetic stimulation (TMS). It provides crucial insight into motor control, neuroplasticity, and neurological conditions. The use of TMS-induced MEPs in clinical and research contexts is contingent upon their intra- and intersession reliability. This study specifically aimed to assess the reliability of two distinct methods for quantifying MEP size: peak-to-peak amplitude (PPA) and the area under the curve (AUC). Establishing the agreement between these quantification methods is critical for ensuring consistent measurements by the same assessor, especially in pre- and post-test designs conducted within and between sessions. Twelve healthy participants volunteered for this study. Thirty MEPs were recorded from each participant using a single-pulse TMS set at 120% of the resting motor threshold (RMT) over two sessions. The first session consisted of two tests (T1 and T2) with a 20-minute rest interval between sets. The second session included one set of tests (T3). Test-retest reliability of MEP amplitude and AUC were assessed using one-way ANOVA and Intraclass Correlation Coefficient (ICC). A one-way ANOVA revealed no significant effect of time on MEP amplitude or AUC value, indicating agreement between sessions. The ICC demonstrated significant intra- and inter-session reliability for PPA. However, correlations between T1-T3 were weak for AUC values. In conclusion, this study suggests that PPA a more reliable measurement than AUC for assessing changes in CSE. Future investigations should explore the reliability of the AUC method in clinical settings or research protocols.

Neuroscience LettersVol. 862
Federation University (AU), Monash Health (AU), Monash University (AU)
Climate action
Openalex Percentile: Top 84%
Transcranial Magnetic Stimulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.