Development of two different eco-friendly label-free platforms for analysis of selumetinib

Selumetinib (SEL) is a recently approved medication for paediatric patients who have neurofibromatosis type 1. It is the first approved therapy for this rare, debilitating, and disfiguring disease. Development of proper analytical platforms for SEL analysis in its marketed pharmaceutical formulation (Koselugo<sup>®</sup> capsules) and blood plasma is highly warranted. Availability of such analytical tools would ensure SEL capsules' quality and effective therapy. This study introduces, for the first time, the development of two label-free and sensitive platforms for SEL quantification in capsules and human plasma. These platforms are microwave-assisted with an ultraviolet absorbance microplate reader (MW-UV) and reverse-phase high-performance liquid chromatography with a photodiode-array detector (HPLC-PDA). Both platforms employed the SEL native UV absorption as an analytical signal. The MW-UV measured the UV absorption in 96-well transparent plates at 255 nm. The HPLC-PDA involved chromatographic separation of SEL and tozasertib (TOZ), internal standard, on a C18 column both were detected at 255 nm. The optimum procedures of both platforms were established and validated following the ICH guidelines. The linearity ranges were 15-500 µg mL<sup>-1</sup> and 0.8-100 µg mL-1, with limits of quantification of 15.3 and 3.5 µg mL<sup>-1</sup>, for MW-UV and HPLC-PDA, resp. Both platforms displayed high precision with relative standard deviation values ≤ 1.8 %, and high accuracy with recovery ranging from 98.3 to 102.3 %. The platforms were successfully applied to quantify SEL in bulk form, Koselugo<sup>®</sup> capsules, and were preliminarily applied to human plasma analysis. Eco-friendliness assessment confirmed the adherence of both platforms to green analytical approaches. MW-UV and HPLC-PDA are simple and fast, enabling high-throughput analysis, thus introducing valuable tools for routine use in quality control and clinical laboratories for SEL quantification.

Authors

Institutions

Publication Details

Journal
Acta Pharmaceutica
Published
2025-06-02
DOI
https://doi.org/10.2478/acph-2025-0013
Primary Topic
Colorectal Cancer Treatments and Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of two different eco-friendly label-free platforms for analysis of selumetinib

Ibrahim Ali Darwish, Sarah Alrubia, Wafa Alshehri, Nourah Z. Alzoman
Acta Pharmaceutica
Colorectal Cancer Treatments and Studies
article

Development of two different eco-friendly label-free platforms for analysis of selumetinib

Ibrahim Ali Darwish, Sarah Alrubia, Wafa Alshehri, Nourah Z. Alzoman
article en

Abstract

Selumetinib (SEL) is a recently approved medication for paediatric patients who have neurofibromatosis type 1. It is the first approved therapy for this rare, debilitating, and disfiguring disease. Development of proper analytical platforms for SEL analysis in its marketed pharmaceutical formulation (Koselugo<sup>®</sup> capsules) and blood plasma is highly warranted. Availability of such analytical tools would ensure SEL capsules' quality and effective therapy. This study introduces, for the first time, the development of two label-free and sensitive platforms for SEL quantification in capsules and human plasma. These platforms are microwave-assisted with an ultraviolet absorbance microplate reader (MW-UV) and reverse-phase high-performance liquid chromatography with a photodiode-array detector (HPLC-PDA). Both platforms employed the SEL native UV absorption as an analytical signal. The MW-UV measured the UV absorption in 96-well transparent plates at 255 nm. The HPLC-PDA involved chromatographic separation of SEL and tozasertib (TOZ), internal standard, on a C18 column both were detected at 255 nm. The optimum procedures of both platforms were established and validated following the ICH guidelines. The linearity ranges were 15-500 µg mL<sup>-1</sup> and 0.8-100 µg mL-1, with limits of quantification of 15.3 and 3.5 µg mL<sup>-1</sup>, for MW-UV and HPLC-PDA, resp. Both platforms displayed high precision with relative standard deviation values ≤ 1.8 %, and high accuracy with recovery ranging from 98.3 to 102.3 %. The platforms were successfully applied to quantify SEL in bulk form, Koselugo<sup>®</sup> capsules, and were preliminarily applied to human plasma analysis. Eco-friendliness assessment confirmed the adherence of both platforms to green analytical approaches. MW-UV and HPLC-PDA are simple and fast, enabling high-throughput analysis, thus introducing valuable tools for routine use in quality control and clinical laboratories for SEL quantification.

Acta PharmaceuticaVol. 75(3)
King Saud University (SA)
King Saud University
Openalex Percentile: Top 81%
Colorectal Cancer Treatments and Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.