A cross-correlator-based timing tool for FemtoMAX

We report on the commissioning of an ultrafast timing diagnostic for measuring a time-offset signal between two different synchronized ultrashort light pulses. The method is based on sum-frequency generation in a nonlinear crystal. The setup is similar to an auto/cross-correlator setup. In this case, one of the beams is a relatively weak diagnostic beam of visible light from a bending magnet at FemtoMAX (10<sup>6</sup> photons pulse<sup>-1</sup> in a 0.2 mm high and 5 mm wide beam) while the other is a relatively intense laser beam (200 µJ pulse<sup>-1</sup>) derived from the same laser that is used to pump the sample in pump/probe experiments. This enables online monitoring of the relative timing of a linear accelerator-based, short-pulse, hard X-ray source and a synchronized visible laser. We show that for a <50 fs full width at half-maximum (FWHM) light pulse from the accelerator and a 50 fs (FWHM) long laser pulse, we can determine the relative timing of the two pulses with an accuracy below 30 fs in a time interval of 4 ps. The advantages and limitations of the method are discussed.

Authors

Institutions

Publication Details

Journal
Journal of Synchrotron Radiation
Published
2025-06-02
DOI
https://doi.org/10.1107/s1600577525003479
Primary Topic
Photorefractive and Nonlinear Optics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A cross-correlator-based timing tool for FemtoMAX

Van‐Thai Pham, David Kroon, Jörgen Larsson, Elin Nilsson et al.
Journal of Synchrotron Radiation
Photorefractive and Nonlinear Optics
article

A cross-correlator-based timing tool for FemtoMAX

Van‐Thai Pham, David Kroon, Jörgen Larsson, Elin Nilsson, A. Jurgilaitis, Massimo Longo, Byungnam Ahn, Raffaella Calarco, J. Carl Ekström, M. Bertelli, Sara De Simone, I. Clementsson
article en

Abstract

We report on the commissioning of an ultrafast timing diagnostic for measuring a time-offset signal between two different synchronized ultrashort light pulses. The method is based on sum-frequency generation in a nonlinear crystal. The setup is similar to an auto/cross-correlator setup. In this case, one of the beams is a relatively weak diagnostic beam of visible light from a bending magnet at FemtoMAX (10<sup>6</sup> photons pulse<sup>-1</sup> in a 0.2 mm high and 5 mm wide beam) while the other is a relatively intense laser beam (200 µJ pulse<sup>-1</sup>) derived from the same laser that is used to pump the sample in pump/probe experiments. This enables online monitoring of the relative timing of a linear accelerator-based, short-pulse, hard X-ray source and a synchronized visible laser. We show that for a <50 fs full width at half-maximum (FWHM) light pulse from the accelerator and a 50 fs (FWHM) long laser pulse, we can determine the relative timing of the two pulses with an accuracy below 30 fs in a time interval of 4 ps. The advantages and limitations of the method are discussed.

Journal of Synchrotron RadiationVol. 32(4)
University of Rome Tor Vergata (IT), Ericsson (Sweden) (SE), Lund University (SE), MAX IV Laboratory (SE), Institute for Microelectronics and Microsystems (IT)
Knut och Alice Wallenbergs Stiftelse, Vetenskapsrådet
Affordable and clean energy
Openalex Percentile: Top 91%
Photorefractive and Nonlinear Optics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.