Effect of Aggregate Size and Water-to-Cement Ratio on the Mechanical Properties of No Fine Aggregate Concrete

The mechanical properties of No-fine aggregate concrete are investigated. This paper consists of two parts: In the first part, three sizes of aggregates (9.5 mm, 12.7 mm, and 19 mm) with two water-to-cement ratios (0.4 and 0.45) were examined. In the second part, specimens made with recycled concrete aggregate with a replacement ratio of 30% by the weight of normal aggregate and a steel fiber of 35 kg/m3 were examined in two water-to-cement ratios (0.4 and 0.45), and an aggregate size of 12.7 mm. The effect of the cement-to-coarse aggregate ratio was also studied; three different ratios (1:2, 1:4, and 1:6) were examined. This study found that the increase in aggregate size and the water-to-cement ratio harmed the compressive, splitting tensile strength, and unit weight of the NO-fine aggregate concrete. The study also found that the compressive and splitting strength declined using recycled concrete aggregate; however, using steel fiber with recycled concrete aggregate improved both.

Authors

Institutions

Publication Details

Journal
Tikrit Journal of Engineering Sciences
Published
2025-05-30
DOI
https://doi.org/10.25130/tjes.32.2.17
Primary Topic
Urban Stormwater Management Solutions
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Aggregate Size and Water-to-Cement Ratio on the Mechanical Properties of No Fine Aggregate Concrete

Muna M. A. Hano, Salwa M. A. Hano
Tikrit Journal of Engineering Sciences
Urban Stormwater Management Solutions
article

Effect of Aggregate Size and Water-to-Cement Ratio on the Mechanical Properties of No Fine Aggregate Concrete

Muna M. A. Hano, Salwa M. A. Hano
article en

Abstract

The mechanical properties of No-fine aggregate concrete are investigated. This paper consists of two parts: In the first part, three sizes of aggregates (9.5 mm, 12.7 mm, and 19 mm) with two water-to-cement ratios (0.4 and 0.45) were examined. In the second part, specimens made with recycled concrete aggregate with a replacement ratio of 30% by the weight of normal aggregate and a steel fiber of 35 kg/m3 were examined in two water-to-cement ratios (0.4 and 0.45), and an aggregate size of 12.7 mm. The effect of the cement-to-coarse aggregate ratio was also studied; three different ratios (1:2, 1:4, and 1:6) were examined. This study found that the increase in aggregate size and the water-to-cement ratio harmed the compressive, splitting tensile strength, and unit weight of the NO-fine aggregate concrete. The study also found that the compressive and splitting strength declined using recycled concrete aggregate; however, using steel fiber with recycled concrete aggregate improved both.

Tikrit Journal of Engineering SciencesVol. 32(2)
University of Mosul (IQ)
University of Mosul
Openalex Percentile: Top 89%
Urban Stormwater Management Solutions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.