Mechanical aging and Retention Forces Assessment of Three Different Modalities of Titanium Milled bar in Implant Retained Mandibular Overdenture: An in-vitro study

Aim: To evaluate the axial retention forces of three different titanium milled bar ‎attachment systems: milled bar , milled bar with supra OT equator, milled bar with supra ‎ball for in implant-retained mandibular overdenture.‎ Materials and methods: An epoxy resin model was constructed simulating completely ‎edentulous mandible. Two implants were inserted in canine regions ,and one in the left ‎central incisor region. Bar attachments designs were constructed by CAD/ CAM ‎technology. Experimental overdentures were to connected to either implants with milled ‎titanium bar attachment (group I), or milled bar with supra ball attachments (group II),or ‎milled bar with supra OT equator attachment (group III). The axial retention force was ‎measured in Newton by universal testing machine for each attachment system at base line ‎‎(T0) to (T11) which simulating five years of the overdenture function (T11 after 5400 ‎cycles of insertion and removal).‎ To compare the three groups to each other; one way-ANOVA followed by Tukey post hoc ‎test, were used to compare between more than two groups in non-related samples.‎ Results: The milled bar with supra ball attachments had a significantly highest retention ‎forces (142 Newton) followed by milled bar with equator attachments (118.65 Newton), ‎while the lowest one was milled bar (111.40 Newton) at base line. The loss of retention ‎force continued throughout the study to reach (22.96 Newton) for milled bar with ball, ‎‎(20.6 Newton) for milled bar with equator, and for milled bar (18.74 Newton) at the end of ‎the study. ‎ conclusion: The retention forces for the milled bar with ball attachment systems ‎demonstrated significantly higher retention forces than those for the milled bar with OT ‎equator, milled bar after cyclic insertion and removal. ‎

Authors

Institutions

Publication Details

Journal
Ain Shams Dental Journal
Published
2025-03-01
DOI
https://doi.org/10.21608/asdj.2025.355959.1823
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mechanical aging and Retention Forces Assessment of Three Different Modalities of Titanium Milled bar in Implant Retained Mandibular Overdenture: An in-vitro study

Shaimaa Radwan, Iman Adel El Asfahani, Hussein Abdelhady Hussein
1 links
Ain Shams Dental Journal
Dental Implant Techniques and Outcomes
article

Mechanical aging and Retention Forces Assessment of Three Different Modalities of Titanium Milled bar in Implant Retained Mandibular Overdenture: An in-vitro study

Shaimaa Radwan, Iman Adel El Asfahani, Hussein Abdelhady Hussein
article en

Abstract

Aim: To evaluate the axial retention forces of three different titanium milled bar ‎attachment systems: milled bar , milled bar with supra OT equator, milled bar with supra ‎ball for in implant-retained mandibular overdenture.‎ Materials and methods: An epoxy resin model was constructed simulating completely ‎edentulous mandible. Two implants were inserted in canine regions ,and one in the left ‎central incisor region. Bar attachments designs were constructed by CAD/ CAM ‎technology. Experimental overdentures were to connected to either implants with milled ‎titanium bar attachment (group I), or milled bar with supra ball attachments (group II),or ‎milled bar with supra OT equator attachment (group III). The axial retention force was ‎measured in Newton by universal testing machine for each attachment system at base line ‎‎(T0) to (T11) which simulating five years of the overdenture function (T11 after 5400 ‎cycles of insertion and removal).‎ To compare the three groups to each other; one way-ANOVA followed by Tukey post hoc ‎test, were used to compare between more than two groups in non-related samples.‎ Results: The milled bar with supra ball attachments had a significantly highest retention ‎forces (142 Newton) followed by milled bar with equator attachments (118.65 Newton), ‎while the lowest one was milled bar (111.40 Newton) at base line. The loss of retention ‎force continued throughout the study to reach (22.96 Newton) for milled bar with ball, ‎‎(20.6 Newton) for milled bar with equator, and for milled bar (18.74 Newton) at the end of ‎the study. ‎ conclusion: The retention forces for the milled bar with ball attachment systems ‎demonstrated significantly higher retention forces than those for the milled bar with OT ‎equator, milled bar after cyclic insertion and removal. ‎

Ain Shams Dental JournalVol. 37(1)
Minia University (EG)
Openalex Percentile: Top 83%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.